Professional construction machinery service

We restore full functionality to your machinery. Contact us

Fill out the form

Diagnostics of LICCON System Error Codes - Liebherr LTM-1070-4.1

The LICCON (Liebherr Computed Control) control system in the Liebherr LTM-1070-4.1 mobile crane constantly monitors the technical condition of electronic components, LSB/CAN bus sensors, and input/output modules. If an irregularity is detected, the system generates a dedicated error code, logs it in memory, and takes appropriate safety measures (e.g., stopping crane movements).

The following catalog contains a list of LICCON system error codes for the Liebherr LTM-1070-4.1 model, including cause descriptions, system reactions, and troubleshooting guidelines.

Service Guide: Computer Diagnostics and LSB Bus in Liebherr Cranes

Modern Liebherr LTM-1070-4.1 mobile cranes base their operation on an advanced LSB (Liebherr-System-Bus) and CAN bus network. All sensors—from pressure transducers in luffing cylinders to angle and length sensors on the telescopic boom—communicate with central units (ZE 0, ZE 1, ZE 2) in real time.

When an LSB communication error appears on the LICCON controller display (e.g., M00020004-M00022567 series errors), first inspect signal cables physically, check for mechanical sensor damage, and verify the condition of plug connectors (e.g., X635, X635A, X635B). Contamination, moisture, or a voltage drop in the sensor power supply circuit are the most common causes of data transmission interruptions.

LICCON Error Code List - Liebherr LTM-1070-4.1

Error Code Error Text / Reaction / Troubleshooting Plug C S
M00210060 ZE 2: Output 0 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:16 E 1
M00210070 ZE 2: Output 0 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:16 E 1
M00210071 ZE 2: Output 0 - short circuit to ground or transistor failure. X72:16 E 1
M00210072 ZE 2: Output 0 - supply from external source. X72:16 E 1
M00210073 ZE 2: Output 0 - open circuit or short circuit to supply voltage/ground. X72:16 E 1
M00210112 ZE 2: Output 1 - short circuit to ground. X72:17 E 1
M00210113 ZE 2: Output 1 - open signal circuit. X72:17 E 1
M00210114 ZE 2: Output 1 - short circuit to supply voltage. X72:17 E 1
M00210154 ZE 2: Output 1 - short circuit to supply voltage. X72:17 E 1
M00210158 ZE 2: Output 1 - positive switching transistor: open circuit. X72:17 E 1
M00210160 ZE 2: Output 1 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:17 E 1
M00210170 ZE 2: Output 1 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:17 E 1
M00210171 ZE 2: Output 1 - short circuit to ground or transistor failure. X72:17 E 1
M00210172 ZE 2: Output 1 - supply from external source. X72:17 E 1
M00210173 ZE 2: Output 1 - open circuit or short circuit to supply voltage/ground. X72:17 E 1
M00210212 ZE 2: Output 2 - short circuit to ground. X72:18 E 1
M00210213 ZE 2: Output 2 - open signal circuit. X72:18 E 1
M00210214 ZE 2: Output 2 - short circuit to supply voltage. X72:18 E 1
M00210254 ZE 2: Output 2 - short circuit to supply voltage. X72:18 E 1
M00210258 ZE 2: Output 2 - positive switching transistor: open circuit. X72:18 E 1
M00210260 ZE 2: Output 2 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:18 E 1
M00210270 ZE 2: Output 2 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:18 E 1
M00210271 ZE 2: Output 2 - short circuit to ground or transistor failure. X72:18 E 1
M00210272 ZE 2: Output 2 - supply from external source. X72:18 E 1
M00210273 ZE 2: Output 2 - open circuit or short circuit to supply voltage/ground. X72:18 E 1
M00210312 ZE 2: Output 3 - short circuit to ground. X72:19 E 1
M00210313 ZE 2: Output 3 - open signal circuit. X72:19 E 1
M00210314 ZE 2: Output 3 - short circuit to supply voltage. X72:19 E 1
M00210354 ZE 2: Output 3 - short circuit to supply voltage. X72:19 E 1
M00210358 ZE 2: Output 3 - positive switching transistor: open circuit. X72:19 E 1
M00210360 ZE 2: Output 3 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:19 E 1
M00210370 ZE 2: Output 3 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:19 E 1
M00210371 ZE 2: Output 3 - short circuit to ground or transistor failure. X72:19 E 1
M00210372 ZE 2: Output 3 - supply from external source. X72:19 E 1
M00210373 ZE 2: Output 3 - open circuit or short circuit to supply voltage/ground. X72:19 E 1
M00210412 ZE 2: Output 4 - short circuit to ground. X72:20 E 1
M00210413 ZE 2: Output 4 - open signal circuit. X72:20 E 1
M00210414 ZE 2: Output 4 - short circuit to supply voltage. X72:20 E 1
M00210454 ZE 2: Output 4 - short circuit to supply voltage. X72:20 E 1
M00210458 ZE 2: Output 4 - positive switching transistor: open circuit. X72:20 E 1
M00210460 ZE 2: Output 4 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:20 E 1
M00210470 ZE 2: Output 4 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:20 E 1
M00210471 ZE 2: Output 4 - short circuit to ground or transistor failure. X72:20 E 1
M00210472 ZE 2: Output 4 - supply from external source. X72:20 E 1
M00210473 ZE 2: Output 4 - open circuit or short circuit to supply voltage/ground. X72:20 E 1
M00210512 ZE 2: Output 5 - short circuit to ground. X72:21 E 1
M00210513 ZE 2: Output 5 - open signal circuit. X72:21 E 1
M00210514 ZE 2: Output 5 - short circuit to supply voltage. X72:21 E 1
M00210554 ZE 2: Output 5 - short circuit to supply voltage. X72:21 E 1
M00210558 ZE 2: Output 5 - positive switching transistor: open circuit. X72:21 E 1
M00210560 ZE 2: Output 5 - safety chain error, defective diode or stuck safety contact
Reaction: Error report, no other reaction.
Troubleshooting: Check safety contact and diode.
X72:21 E 1
M00210570 ZE 2: Output 5 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:21 E 1
M00210571 ZE 2: Output 5 - short circuit to ground or transistor failure. X72:21 E 1
M00210572 ZE 2: Output 5 - supply from external source. X72:21 E 1
M00210573 ZE 2: Output 5 - open circuit or short circuit to supply voltage/ground. X72:21 E 1
M00210612 ZE 2: Output 6 - short circuit to ground. X72:22 E 1
M00210613 ZE 2: Output 6 - open signal circuit. X72:22 E 1
M00210614 ZE 2: Output 6 - short circuit to supply voltage. X72:22 E 1
M00210654 ZE 2: Output 6 - short circuit to supply voltage. X72:22 E 1
M00210658 ZE 2: Output 6 - positive switching transistor: open circuit. X72:22 E 1
M00210670 ZE 2: Output 6 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:22 E 1
M00210671 ZE 2: Output 6 - short circuit to ground or transistor failure. X72:22 E 1
M00210672 ZE 2: Output 6 - supply from external source. X72:22 E 1
M00210673 ZE 2: Output 6 - open circuit or short circuit to supply voltage/ground. X72:22 E 1
M00210712 ZE 2: Output 7 - short circuit to ground. X72:23 E 1
M00210713 ZE 2: Output 7 - open signal circuit. X72:23 E 1
M00210714 ZE 2: Output 7 - short circuit to supply voltage. X72:23 E 1
M00210754 ZE 2: Output 7 - short circuit to supply voltage. X72:23 E 1
M00210758 ZE 2: Output 7 - positive switching transistor: open circuit. X72:23 E 1
M00210770 ZE 2: Output 7 - measuring system defect
Reaction: Crane operation not possible, logged in error list.
X72:23 E 1
M00210771 ZE 2: Output 7 - short circuit to ground or transistor failure. X72:23 E 1
M00210772 ZE 2: Output 7 - supply from external source. X72:23 E 1
M00210773 ZE 2: Output 7 - open circuit or short circuit to supply voltage/ground. X72:23 E 1
M00214959 ZE 2: Supply voltage missing for all outputs. X72 E 1
M00215059 ZE 2: Supply voltage missing for output group 0. X72:12 E 1
M00215159 ZE 2: Supply voltage missing for output group 1. X72:24 E 1
M00215259 ZE 2: Supply voltage missing for output group 2. X72:25 E 1
M00215359 ZE 2: Supply voltage missing for output group 3. X72:13 E 1

Looking for reliable parts for your machine?

Thousands of replacement parts and original components available in stock with fast delivery

LICCON Error Code List - Liebherr LTM-1070-4.1

Error Code Error Text / Reaction / Troubleshooting Plug C S
M00220004 ZE 2: LSB participant address 0 - signal level exceeded
Reaction: Error report, no other reaction.
Troubleshooting: Check sensor mounting and pre-attenuation, clean off dirt, replace sensor if damaged.
X635B:z14/z16 E 1
M00220005 ZE 2: LSB participant address 0 - signal level below minimum
Reaction: Error report, no other reaction.
Troubleshooting: Check sensor mounting, remove blockage or damage, replace if necessary.
X635B:z14/z16 E 1
M00220018 ZE 2: LSB participant address 0 - temperature exceeded
Reaction: Error report, no other reaction.
Troubleshooting: Use sensor within permissible temperature range, check heat supply and dissipation.
X635B:z14/z16 E 0
M00220050 ZE 2: LSB participant address 0 - reports incorrect sensor type
Reaction: Logged in error memory, interpretation according to set type features.
Troubleshooting: Check address assignment via LSB screen, install correct sensor.
X635B:z14/z16 E 2
M00220051 ZE 2: LSB participant address 0 - not configured for block transfer
Reaction: Logged in error memory, no block transfer.
Troubleshooting: Configuration problem, upload new software.
X635B:z14/z16 E 2
M00220053 ZE 2: LSB participant address 0 - stopped responding or disconnected during operation
Reaction: Deactivation of participant, data buffer set to 0.
Troubleshooting: Check connection, if correct - replace sensor.
X635B:z14/z16 E 1
M00220054 ZE 2: LSB participant address 0 - has different settings (parameters) than set values
Reaction: Logged in error memory, incorrect sensor data.
Troubleshooting: Check parameters via LSB screen, restore sensor default values.
X635B:z14/z16 E 2
M00220064 ZE 2: LSB participant address 0 - reports permissible error in self-test
Reaction: Logged in error memory, sensor still operates correctly.
Troubleshooting: Check and clean sensor, replace if repeated.
X635B:z14/z16 E 1
M00220065 ZE 2: LSB participant address 0 - reports impermissible error in self-test
Reaction: Correct operation not guaranteed.
Troubleshooting: Replace sensor immediately.
X635B:z14/z16 E 2
M00220066 ZE 2: LSB participant address 0 - incompatible software version
Reaction: Attempting to continue operation with sensor.
Troubleshooting: Replace sensor with new element.
X635B:z14/z16 E 2
M00220067 ZE 2: LSB participant address 0 - does not support data download function. X635B:z14/z16 E 1
M00220104 ZE 2: LSB participant address 1 - signal level exceeded
Troubleshooting: Check sensor installation, clean, replace if damaged.
X635B:z14/z16 E 1
M00220105 ZE 2: LSB participant address 1 - signal level below minimum
Troubleshooting: Check installation and clear obstruction/damage to sensor.
X635B:z14/z16 E 1
M00220118 ZE 2: LSB participant address 1 - sensor temperature exceeded. X635B:z14/z16 E 0
M00220150 ZE 2: LSB participant address 1 - reports incorrect sensor type. X635B:z14/z16 E 2
M00220151 ZE 2: LSB participant address 1 - not configured for block transfer. X635B:z14/z16 E 2
M00220153 ZE 2: LSB participant address 1 - communication loss or disconnected during operation. X635B:z14/z16 E 1
M00220154 ZE 2: LSB participant address 1 - parameters mismatch with configuration. X635B:z14/z16 E 2
M00220164 ZE 2: LSB participant address 1 - reports tolerated self-test error. X635B:z14/z16 E 1
M00220165 ZE 2: LSB participant address 1 - reports critical self-test error, replacement required. X635B:z14/z16 E 2
M00220166 ZE 2: LSB participant address 1 - incompatible sensor software version. X635B:z14/z16 E 2
M00220167 ZE 2: LSB participant address 1 - no data download support. X635B:z14/z16 E 1
M00220204 ZE 2: LSB participant address 2 - signal level exceeded. X635B:z14/z16 E 1
M00220205 ZE 2: LSB participant address 2 - signal below minimum level. X635B:z14/z16 E 1
M00220218 ZE 2: LSB participant address 2 - temperature too high. X635B:z14/z16 E 0
M00220250 ZE 2: LSB participant address 2 - incorrect sensor type. X635B:z14/z16 E 2
M00220251 ZE 2: LSB participant address 2 - not configured for block transfer. X635B:z14/z16 E 2
M00220253 ZE 2: LSB participant address 2 - signal loss/participant disconnected. X635B:z14/z16 E 1
M00220254 ZE 2: LSB participant address 2 - invalid configuration parameters. X635B:z14/z16 E 2
M00220264 ZE 2: LSB participant address 2 - permissible self-test error. X635B:z14/z16 E 1
M00220265 ZE 2: LSB participant address 2 - critical self-test error, replace sensor. X635B:z14/z16 E 2
M00220266 ZE 2: LSB participant address 2 - incompatible software. X635B:z14/z16 E 2
M00220267 ZE 2: LSB participant address 2 - no software download support. X635B:z14/z16 E 1

Hydraulics breakdown on the construction site?

Fast diagnosis and repair of hydraulic systems without needing to transport the machine

LICCON Error Code List - Liebherr LTM-1070-4.1

Error Code Error Text / Reaction / Troubleshooting Plug C S
M00220904 ZE 2: LSB participant address 9 - signal level exceeded. X635B:z14/z16 E 1
M00220905 ZE 2: LSB participant address 9 - signal level below minimum. X635B:z14/z16 E 1
M00220918 ZE 2: LSB participant address 9 - temperature too high. X635B:z14/z16 E 0
M00220950 ZE 2: LSB participant address 9 - reports incorrect sensor type. X635B:z14/z16 E 2
M00220951 ZE 2: LSB participant address 9 - not configured for block transfer. X635B:z14/z16 E 2
M00220953 ZE 2: LSB participant address 9 - no response / withdrawn during operation. X635B:z14/z16 E 1
M00220954 ZE 2: LSB participant address 9 - invalid parameter configuration. X635B:z14/z16 E 2
M00220964 ZE 2: LSB participant address 9 - permissible self-test error. X635B:z14/z16 E 1
M00220965 ZE 2: LSB participant address 9 - critical self-test error. X635B:z14/z16 E 2
M00220966 ZE 2: LSB participant address 9 - incompatible software. X635B:z14/z16 E 2
M00220967 ZE 2: LSB participant address 9 - no download function. X635B:z14/z16 E 1
M00222004 ZE 2: LSB participant address 20 - signal level exceeded. X635B:z14/z16 E 1
M00222005 ZE 2: LSB participant address 20 - signal level below minimum. X635B:z14/z16 E 1
M00222018 ZE 2: LSB participant address 20 - temperature exceeded. X635B:z14/z16 E 0
M00222050 ZE 2: LSB participant address 20 - sensor type error. X635B:z14/z16 E 2
M00222051 ZE 2: LSB participant address 20 - no block configuration. X635B:z14/z16 E 2
M00222053 ZE 2: LSB participant address 20 - no communication. X635B:z14/z16 E 1
M00222054 ZE 2: LSB participant address 20 - parameters mismatch. X635B:z14/z16 E 2
M00222064 ZE 2: LSB participant address 20 - minor self-test error. X635B:z14/z16 E 1
M00222065 ZE 2: LSB participant address 20 - severe self-test error. X635B:z14/z16 E 2
M00222066 ZE 2: LSB participant address 20 - incompatible software. X635B:z14/z16 E 2
M00222067 ZE 2: LSB participant address 20 - no download support. X635B:z14/z16 E 1
M00222104 ZE 2: LSB participant address 21 - signal level exceeded. X635B:z14/z16 E 1
M00222105 ZE 2: LSB participant address 21 - signal below minimum. X635B:z14/z16 E 1
M00222118 ZE 2: LSB participant address 21 - temperature exceeded. X635B:z14/z16 E 0
M00222150 ZE 2: LSB participant address 21 - faulty sensor type. X635B:z14/z16 E 2
M00222151 ZE 2: LSB participant address 21 - no block configuration. X635B:z14/z16 E 2
M00222153 ZE 2: LSB participant address 21 - sensor not reporting. X635B:z14/z16 E 1
M00222154 ZE 2: LSB participant address 21 - parameter deviation. X635B:z14/z16 E 2
M00222164 ZE 2: LSB participant address 21 - small self-test error. X635B:z14/z16 E 1
M00222165 ZE 2: LSB participant address 21 - disqualifying self-test error. X635B:z14/z16 E 2
M00222166 ZE 2: LSB participant address 21 - incompatible software version. X635B:z14/z16 E 2
M00222167 ZE 2: LSB participant address 21 - download function unavailable. X635B:z14/z16 E 1
M00222304 ZE 2: LSB participant address 23 - signal level exceeded. X635B:z14/z16 E 1
M00222305 ZE 2: LSB participant address 23 - minimum level not reached. X635B:z14/z16 E 1
M00222318 ZE 2: LSB participant address 23 - temperature exceeded. X635B:z14/z16 E 0
M00222350 ZE 2: LSB participant address 23 - incorrect sensor type. X635B:z14/z16 E 2
M00222351 ZE 2: LSB participant address 23 - no block configuration. X635B:z14/z16 E 2
M00222353 ZE 2: LSB participant address 23 - disconnected/no signal. X635B:z14/z16 E 1
M00222354 ZE 2: LSB participant address 23 - sensor parameter error. X635B:z14/z16 E 2
M00222364 ZE 2: LSB participant address 23 - tolerable self-test error. X635B:z14/z16 E 1
M00222365 ZE 2: LSB participant address 23 - critical self-test error. X635B:z14/z16 E 2
M00222366 ZE 2: LSB participant address 23 - outdated software. X635B:z14/z16 E 2
M00222367 ZE 2: LSB participant address 23 - download function not supported. X635B:z14/z16 E 1
M00222404 ZE 2: LSB participant address 24 - signal level exceeded. X635B:z14/z16 E 1
M00222405 ZE 2: LSB participant address 24 - signal level too low. X635B:z14/z16 E 1
M00222418 ZE 2: LSB participant address 24 - temperature too high. X635B:z14/z16 E 0
M00222450 ZE 2: LSB participant address 24 - incorrect sensor type. X635B:z14/z16 E 2
M00222451 ZE 2: LSB participant address 24 - no block configuration. X635B:z14/z16 E 2
M00222453 ZE 2: LSB participant address 24 - withdrawn or no signal. X635B:z14/z16 E 1
M00222454 ZE 2: LSB participant address 24 - invalid parameters. X635B:z14/z16 E 2
M00222464 ZE 2: LSB participant address 24 - tolerated self-test error. X635B:z14/z16 E 1
M00222465 ZE 2: LSB participant address 24 - critical self-test error. X635B:z14/z16 E 2
M00222466 ZE 2: LSB participant address 24 - incompatible software. X635B:z14/z16 E 2
M00222467 ZE 2: LSB participant address 24 - no download function. X635B:z14/z16 E 1
M00222604 ZE 2: LSB participant address 26 - signal level exceeded. X635B:z14/z16 E 1
M00222605 ZE 2: LSB participant address 26 - signal below minimum level. X635B:z14/z16 E 1
M00222618 ZE 2: LSB participant address 26 - temperature exceeded. X635B:z14/z16 E 0
M00222650 ZE 2: LSB participant address 26 - incorrect sensor type. X635B:z14/z16 E 2
M00222651 ZE 2: LSB participant address 26 - no block configuration. X635B:z14/z16 E 2
M00222653 ZE 2: LSB participant address 26 - stopped responding. X635B:z14/z16 E 1
M00222654 ZE 2: LSB participant address 26 - invalid sensor parameters. X635B:z14/z16 E 2
M00222664 ZE 2: LSB participant address 26 - acceptable self-test error. X635B:z14/z16 E 1
M00222665 ZE 2: LSB participant address 26 - critical self-test error. X635B:z14/z16 E 2
M00222666 ZE 2: LSB participant address 26 - incompatible software. X635B:z14/z16 E 2
M00222667 ZE 2: LSB participant address 26 - no download function. X635B:z14/z16 E 1
M00222704 ZE 2: LSB participant address 27 - signal level exceeded. X635B:z14/z16 E 1
M00222705 ZE 2: LSB participant address 27 - signal below minimum. X635B:z14/z16 E 1
M00222718 ZE 2: LSB participant address 27 - temperature exceeded. X635B:z14/z16 E 0
M00222750 ZE 2: LSB participant address 27 - incorrect sensor type. X635B:z14/z16 E 2
M00222751 ZE 2: LSB participant address 27 - no block configuration. X635B:z14/z16 E 2
M00222753 ZE 2: LSB participant address 27 - disconnected during operation. X635B:z14/z16 E 1
M00222754 ZE 2: LSB participant address 27 - invalid sensor parameters. X635B:z14/z16 E 2
M00222764 ZE 2: LSB participant address 27 - tolerated self-test error. X635B:z14/z16 E 1
M00222765 ZE 2: LSB participant address 27 - critical self-test error. X635B:z14/z16 E 2
M00222766 ZE 2: LSB participant address 27 - outdated software. X635B:z14/z16 E 2
M00222767 ZE 2: LSB participant address 27 - no download function. X635B:z14/z16 E 1
M00222804 ZE 2: LSB participant address 28 - signal level exceeded. X635B:z14/z16 E 1
M00222805 ZE 2: LSB participant address 28 - signal below minimum. X635B:z14/z16 E 1
M00222818 ZE 2: LSB participant address 28 - temperature exceeded. X635B:z14/z16 E 0
M00222850 ZE 2: LSB participant address 28 - faulty sensor type. X635B:z14/z16 E 2
M00222851 ZE 2: LSB participant address 28 - no block configuration. X635B:z14/z16 E 2
M00222853 ZE 2: LSB participant address 28 - no communication. X635B:z14/z16 E 1
M00222854 ZE 2: LSB participant address 28 - bad parameter configuration. X635B:z14/z16 E 2
M00222864 ZE 2: LSB participant address 28 - minor self-test error. X635B:z14/z16 E 1
M00222865 ZE 2: LSB participant address 28 - critical self-test error. X635B:z14/z16 E 2
M00222866 ZE 2: LSB participant address 28 - incompatible software. X635B:z14/z16 E 2
M00222867 ZE 2: LSB participant address 28 - no download support. X635B:z14/z16 E 1
M00222904 ZE 2: LSB participant address 29 - signal level exceeded. X635B:z14/z16 E 1
M00222905 ZE 2: LSB participant address 29 - signal below minimum level. X635B:z14/z16 E 1
M00222918 ZE 2: LSB participant address 29 - excessive sensor temperature. X635B:z14/z16 E 0
M00222950 ZE 2: LSB participant address 29 - incorrect sensor type. X635B:z14/z16 E 2
M00222951 ZE 2: LSB participant address 29 - no block configuration. X635B:z14/z16 E 2
M00222953 ZE 2: LSB participant address 29 - no data read / disconnected. X635B:z14/z16 E 1
M00222954 ZE 2: LSB participant address 29 - invalid parameters in configuration. X635B:z14/z16 E 2
M00222964 ZE 2: LSB participant address 29 - permissible self-test error. X635B:z14/z16 E 1
M00222965 ZE 2: LSB participant address 29 - impermissible self-test error. X635B:z14/z16 E 2
M00222966 ZE 2: LSB participant address 29 - incompatible software. X635B:z14/z16 E 2
M00222967 ZE 2: LSB participant address 29 - no download support. X635B:z14/z16 E 1

Engine performance issues with your machine?

We perform comprehensive diagnostics and engine repairs directly at the customer's site

LICCON Error Code List - Liebherr LTM-1070-4.1

Error Code Error Text / Reaction / Troubleshooting Plug C S
M00223252 ZE 2: LSB control data transmission - detected bus collision, communication interrupted
Reaction: Logged in error memory, controller withdraws from the bus.
Troubleshooting: Self-recovers in case of temporary fault, otherwise check sensor addressing.
X635B:z14/z16 E 0
M00223255 ZE 2: LSB data transmission - connection damaged/defective, short circuit to supply voltage
Troubleshooting: Check bus line, sensors (disconnect one by one), and bus fuse on the circuit board.
X635B:z14/z16 E 2
M00223256 ZE 2: LSB data transmission - connection damaged/defective, no power supply or short circuit to ground
Troubleshooting: Check bus line, sensors, and bus fuse on the circuit board.
X635B:z14/z16 E 2
M00223257 ZE 2: LSB data transmission - network reset recognized (restarting transmission)
Troubleshooting: Successively disconnect sensors from the bus to identify defective component.
X635B:z14/z16 E 1
M00223258 ZE 2: LSB data transmission - participant with incorrect transmission speed (baud rate) recognized. X635B:z14/z16 E 0
M00223259 ZE 2: LSB data transmission - bus communication breakdown recognized. X635B:z14/z16 E 0
M00223260 ZE 2: LSB data transmission - controller error: no command to execute. X635B:z14/z16 E 2
M00223261 ZE 2: LSB data transmission - controller error: undefined message received. X635B:z14/z16 E 2
M00223262 ZE 2: LSB data transmission - controller error: initialization error. New software required. X635B:z14/z16 E 2
M00225214 ZE 2: Input 4 - short circuit to supply voltage
Reaction: Value set to zero, error bits set and error displayed.
Troubleshooting: Check input, test/replace sensor.
X635B:d10 E 1
M00225215 ZE 2: Input 4 - open electrical circuit.
Troubleshooting: Check input and sensor.
X635B:d10 E 1
M00225702 ZE 2: Input 9 - sensor failure, short circuit to supply voltage.
Troubleshooting: Check power supply, LICCON input, signal line, and sensor.
X635B:d20 E 1
M00230500 ZE 2: Remote control (transmitter) - maximum radio transmission cycle exceeded
Reaction: Radio control deactivated.
Troubleshooting: Check radio receiver/transmitter (battery!).
- E 1
M00230501 ZE 2: Remote control (receiver) - disturbed or interrupted connection with receiver
Troubleshooting: Check serial connection cable of the receiver.
- E 1
M00230502 ZE 2: Remote control (receiver) - transmission error (CRC)
Troubleshooting: Check connection cable and radio modules.
- E 1
M00230503 ZE 2: Remote control - transmission cycle flag exceeded. - E 1
M00230504 ZE 2: Remote control - message transmission cycle exceeded. - E 1
M00232000 ZE 2: Winch 1 control - rotation not recognized with winch actuated
Troubleshooting: Check LICCON output, cables, incremental sensor, and winch brake.
- E 1
M00232100 ZE 2: Winch 2 control - rotation not recognized with winch actuated
Troubleshooting: Check LICCON output, cables, incremental sensor, and brake.
- E 1
M00233001 ZE 2: Auxiliary equipment control - luffing shutdown and fly jib shutdown selected simultaneously
Reaction: Operational shutdown, override not possible.
Troubleshooting: Check ZE2 input board or remote control transmitter.
- E 1
M00233900 ZE 2: Crane control - engine speed signal defective or missing
Reaction: Set to medium speed for power limitation.
Troubleshooting: Check engine electronics.
- E 1
M00233901 ZE 2: Crane control - engine torque signal erroneous or missing
Reaction: Set to medium torque for power limitation.
- E 1
M00233930 ZE 2: Crane control - pressure sensor "P" or "LS" signal defective/missing
Reaction: Load-Sensing regulation disabled.
Troubleshooting: Check power supply, LICCON input, and pressure sensors.
- E 1
M00233933 ZE 2: Pressure transducer "P" signal below lower limit value (no pressure!). - E 1
M00233934 ZE 2: Pressure transducer "P" signal exceeded lower limit value. - E 1
M00233935 ZE 2: Pressure transducer "LS" signal below lower limit value. - E 1
M00233936 ZE 2: Pressure transducer "LS" signal exceeded lower limit value. - E 1
M00233937 ZE 2: Pressure transducers "P" and "LS" outside permissible signal difference
Troubleshooting: Replace pressure transducer "P" and/or "LS".
- E 1
M00233938 ZE 2: Pressure transducer "P" signal greater than "LS" (with no pressure!)
Troubleshooting: Swap pressure transducers "P" and "LS".
- E 1
M00234200 ZE 2: Right armrest instruments - master switch (joystick) 1Y: both directional contacts closed simultaneously.
Troubleshooting: Check wiring for short circuits, disconnect master switch to verify.
- E 1
M00234201 ZE 2: Right armrest instruments - master switch 1X: both directional contacts closed simultaneously. - E 1
M00234202 ZE 2: Right armrest instruments - master switch 1Y: directional contact without zero position signal. - E 1
M00234203 ZE 2: Right armrest instruments - master switch 1X: directional contact without zero position signal. - E 1
M00234204 ZE 2: Right armrest instruments - master switch 1Y: analog signal shorted to supply voltage. - E 1
M00234205 ZE 2: Right armrest instruments - master switch 1X: analog signal shorted to supply voltage. - E 1
M00234208 ZE 2: Right armrest instruments - master switch 1Y: analog signal open or shorted to ground. - E 1
M00234209 ZE 2: Right armrest instruments - master switch 1X: analog signal open or shorted to ground. - E 1
M00234312 ZE 2: Left armrest instruments - master switch 2Y: both directional contacts closed simultaneously. - E 1
M00234314 ZE 2: Left armrest instruments - master switch 2Y: directional contact without zero position signal. - E 1
M00234316 ZE 2: Left armrest instruments - master switch 2Y: analog signal shorted to supply voltage. - E 1
M00234320 ZE 2: Left armrest instruments - master switch 2Y: analog signal open or shorted to ground. - E 1