LICCON Error Code Diagnostics for Liebherr LTM-1070-4.1 Mobile Crane (I/O Modules E/A 2, 3, and 4)

The LICCON (Liebherr Computed Control) control system in the Liebherr LTM-1070-4.1 mobile crane continuously monitors the operating parameters of hydraulic, pneumatic, and drive systems as well as communication buses. The following summary covers detailed fault code documentation (pages 206–227 of the LEC technical documentation) assigned to E/A-Modul 2, E/A-Modul 3, and E/A-Modul 4, along with system reactions, recommended corrective actions, and diagnostic connector designations.

Service Block 1: Role of Input/Output Modules (E/A-Modul) and the LSB Bus in Liebherr LTM-1070-4.1

In the electronic architecture of the Liebherr LTM-1070-4.1 crane, input/output modules (E/A-Modul 2, 3, and 4) act as distributed signal concentrators connecting actuator sensors, proportional valves, and limit switches to the central processing units (ZE). Communication takes place via two channels: a high-speed CAN bus (responsible for data exchange with the engine, transmission, and ABS/ASR system) and the proprietary LSB (Liebherr System Bus) sensor bus. When diagnosing fault codes, first verify the continuity of the bus wiring, the condition of the contacts in multi-pin connectors (e.g., X625, X633, X643), and the stability of the 24 V DC power supply.

Error Codes for E/A-Modul 2 (LSB-B Communication, CAN Bus, and Chassis Operation)

The first part of the summary (pages 206–211 of the documentation) covers transmission errors on the LSB-B bus, cycle time exceedances of CAN network participants, communication disruptions with the engine and transmission control units, and interlocks of suspension, leveling, and axle locking functions.

Error Code Fault Description / System Reaction / Remedy Connector (Stecker) K/W
M00287252 E/A-Module 2: LSB-B data transfer control detected bus collisions, communication interrupted.
Reaction: Stored in fault memory, controller withdraws from bus, possible reset and network restart.
Remedy: For temporary interference, the error clears automatically; otherwise, check sensor address assignment.
X623:4/6 E/0
M00287255 E/A-Module 2: LSB-B data transfer control – faulty bus connection, short circuit to supply voltage.
Reaction: Stored in fault memory, controller continuously attempts to restart the bus.
Remedy: Check bus cable, disconnect sensors and check bus board for short circuits, inspect bus fuse.
X623:4/6 E/2
M00287256 E/A-Module 2: LSB-B data transfer control – faulty bus connection, no power supply or short circuit to ground.
Reaction: Stored in fault memory, controller continuously attempts to restart the bus.
Remedy: Check bus cable, sensors, and bus board for short circuits and open circuits, check fuse.
X623:4/6 E/2
M00287257 E/A-Module 2: LSB-B data transfer control detected network reset (data transfer restarted).
Reaction: Stored in fault memory, controller restarts and initializes the network.
Remedy: Check bus lines, disconnect sensors one by one from the bus to locate the source of interference, and replace the defective component.
X623:4/6 E/1
M00287258 E/A-Module 2: LSB-B data transfer control detected a participant with an incorrect transmission speed (baud rate).
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Error is automatically eliminated by the system; check sensor address assignment.
X623:4/6 E/0
M00287259 E/A-Module 2: LSB-B data transfer control detected a communication interruption on the bus.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Fault is automatically eliminated by the controller via network restart.
X623:4/6 E/0
M00287260 E/A-Module 2: LSB-B data transfer controller error – command not executed.
Reaction: Stored in fault memory, controller continues operating and waits for bus participant connection.
Remedy: For temporary interference, the error disappears on its own; in case of incorrect configuration, upload new software.
X623:4/6 E/2
M00287261 E/A-Module 2: LSB-B data transfer controller error – undefined message occurred.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: For temporary faults, the system clears the error automatically; otherwise, a software update is required.
X623:4/6 E/2
M00287262 E/A-Module 2: LSB-B data transfer controller error – initialization error.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Uploading new software is required to eliminate the error.
X623:4/6 E/2
M00287530 E/A-Module 2: CAN participant (engine) – data transfer cycle time exceeded.
Reaction: CAN information from the participant exceeded the defined cycle time.
Remedy: If the bus is intact, check the connection of the E/A module to the CAN network or replace the E/A module.
X625:5/6 E/0
M00287531 E/A-Module 2: CAN participant (engine) – missing or faulty data transfer, maximum cycle time exceeded.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check bus lines/star point (zero point) and the faulty bus participant.
X625:5/6 E/1
M00287630 E/A-Module 2: CAN participant (transmission) – data transfer cycle time exceeded.
Reaction: CAN information exceeded the defined cycle time.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/0
M00287631 E/A-Module 2: CAN participant (transmission) – missing or faulty data transfer, maximum cycle time exceeded.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/1
M00287730 E/A-Module 2: CAN participant ABV (ABS/ASR) – data transfer cycle time exceeded.
Reaction: CAN information exceeded the defined cycle time.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/0
M00287731 E/A-Module 2: CAN participant ABV (ABS/ASR) – missing or faulty data transfer, maximum cycle time exceeded.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/1
M00288430 E/A-Module 2: CAN participant E/A-Module 2 – data transfer cycle time exceeded.
Reaction: CAN information exceeded the defined cycle time.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/0
M00288431 E/A-Module 2: CAN participant E/A-Module 2 – missing or faulty data transfer, maximum cycle time exceeded.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/1
M00288530 E/A-Module 2: CAN participant E/A-Module 1 – data transfer cycle time exceeded.
Reaction: CAN information exceeded the defined cycle time.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/0
M00288531 E/A-Module 2: CAN participant E/A-Module 1 – missing or faulty data transfer, maximum cycle time exceeded.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check bus lines/star point and the faulty bus participant.
X625:5/6 E/1
M00289900 E/A-Module 2: CAN data transfer control – internal error during controller register test.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul.
X625:5/6 E/2
M00289901 E/A-Module 2: CAN data transfer control – internal error during controller RAM test.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul.
X625:5/6 E/2
M00289902 E/A-Module 2: CAN data transfer control – software configuration error.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul, check software (ZE test system).
X625:5/6 E/2
M00289903 E/A-Module 2: CAN data transfer control – transmission interrupted after continuous error.
Reaction: CAN transmission is interrupted.
Remedy: Check bus lines/star point, replace star point or E/A-Modul.
X625:5/6 E/1
M00289910 E/A-Module 2: CAN data transfer control – short-term bus connection error.
Reaction: Module rejoins bus transmission.
Remedy: Check bus lines/star point, disconnect individual network participants and verify if the error clears.
X625:5/6 E/0
M00289911 E/A-Module 2: CAN data transfer control – permanent bus connection error.
Reaction: Cyclic attempts to rejoin the module to bus transmission.
Remedy: Check bus lines/star point, disconnect individual network participants and check if the error has cleared.
X625:5/6 E/1
M00289920 E/A-Module 2: CAN data transfer control – active participant not responding.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check error report for missing participants in the ZE test system.
X625:5/6 E/0
M00289921 E/A-Module 2: CAN data transfer control – no active participant responding.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: If the bus is intact, check the connection of the E/A module to the CAN network or replace the E/A module.
X625:5/6 E/1
M00289950 E/A-Module 2: CAN data transfer control – invalid test system command.
Reaction: No response to an unknown test system control command in the CAN software.
Remedy: Check software (test system).
X625:5/6 E/1
M00292001 E/A-Module 2: Engine control – prolonged communication disruption E/A-Module <-> engine control unit.
Reaction: Engine control unit and E/A module switch to limp-home (emergency) RPM.
Remedy: Check engine control unit, E/A module, and CAN bus connections.
- E/1
M00292110 E/A-Module 2: Transmission control – prolonged communication disruption gear selector <-> transmission.
Reaction: Transmission control unit and E/A module switch to emergency driving program.
Remedy: Check transmission control unit, E/A module, and CAN bus connection.
- E/1
M00292111 E/A-Module 2: Transmission control – prolonged communication disruption gear selector in crane cab <-> E/A-Module.
Reaction: After restoring connection, selecting neutral position "N" is required first.
Remedy: Check LSB connection ZE<>E/A-Module, drive switch in crane cab, or connection to ZE.
- E/1
M00294190 E/A-Module 2: Missing LSB bus participant – central processing unit ZE.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and network participant.
- E/1
M00294191 E/A-Module 2: Missing LSB bus participant – E/A-Module 1.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 1.
- E/1
M00294193 E/A-Module 2: Missing LSB bus participant – E/A-Module 3.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 3.
- E/1
M00294194 E/A-Module 2: Missing LSB bus participant – E/A-Module 4.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 4.
- E/1
M00294195 E/A-Module 2: Missing LSB bus participant – E/A-Module 5.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 5.
- E/1
M00295550 E/A-Module 2: Axle suspension operation – selected in chassis operating mode with outriggers retracted.
Reaction: Function is not executed.
Remedy: Extend outriggers (outrigger limit switches must be active).
- B/-
M00295645 E/A-Module 2: Leveling/filling/draining operation – supply pressure too low.
Reaction: Function is not executed.
Remedy: Start engine, increase engine speed, or check supply pressure.
- B/-
M00295650 E/A-Module 2: Leveling/filling/draining operation – selected in chassis operating mode with outriggers retracted.
Reaction: Function is not executed.
Remedy: Extend outriggers (outrigger limit switches must be active).
- B/-
M00296125 E/A-Module 2: Rear axle unlocking operation – inactive input (15UW, 150W, 15UWOW) on E/A-Module 2.
Reaction: Function is not executed.
Remedy: Check inputs (15UW, 150W, 15UWOW) on E/A-Module 2 and LSB connection.
- B/-
M00296150 E/A-Module 2: Rear axle unlocking operation – selected in chassis operating mode with outriggers retracted.
Reaction: Function is not executed.
Remedy: Extend outriggers (outrigger limit switches must be active).
- B/-
M00296151 E/A-Module 2: Rear axle unlocking operation – selected in superstructure operating mode with outriggers retracted.
Reaction: Function is not executed.
Remedy: Extend outriggers (outrigger limit switches must be active).
- B/-
M00296225 E/A-Module 2: Rear axle steering operation – inactive input (15UW, 150W, 15UWOW) on E/A-Module 2.
Reaction: Function is not executed.
Remedy: Check inputs (15UW, 150W, 15UWOW) on E/A-Module 2 and LSB connection.
- B/-

 

New Holland Machinery Service – Keep Your Equipment Running Smoothly

We overhaul combine harvester engines and repair excavators, providing professional service support

 

Error Codes for E/A-Modul 3 (OS-C167 System Errors and DEA and E Outputs/Inputs)

The next range (pages 212–217 of the documentation) covers diagnostics of E/A-Modul 3, including OS-C167 processor initialization errors, EPROM/FLASH and RAM memory errors, DEA0–DEA7 digital output errors (connector X633), and E0–E7 voltage input errors (connector X632).

Error Code Fault Description / System Reaction / Remedy Connector (Stecker) K/W
M00361001 E/A-Module 3: OS-C167 system error – processor register initialization error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00361002 E/A-Module 3: OS-C167 system error – checksum error during initialization in EPROM/FLASH memory.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00361006 E/A-Module 3: OS-C167 system error – RAM memory initialization error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00361013 E/A-Module 3: OS-C167 system error – incorrect checksum in EPROM/FLASH memory.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00361016 E/A-Module 3: OS-C167 system error – system / controller watchdog timer expired.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00361068 E/A-Module 3: OS-C167 system error – illegal interrupt.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00361071 E/A-Module 3: OS-C167 system error – incorrect configuration or firmware.
Reaction: Error indicated on the display.
Remedy: Re-download software from the central processing unit ZE.
- E/2
M00361080 E/A-Module 3: OS-C167 system error – critical internal software error.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00361082 E/A-Module 3: OS-C167 system error – hardware watchdog circuit error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00361088 E/A-Module 3: OS-C167 system error – configuration does not match software version.
Reaction: Error indicated on the display.
Remedy: Mismatch between EAM software and LICCON configuration – check LICCON configuration and perform a download to EAM.
- E/2
M00372052 E/A-Module 3: Input/output DEA0 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:17 E/1
M00372053 E/A-Module 3: Input/output DEA0 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:17 E/1
M00372054 E/A-Module 3: Input/output DEA0 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:17 E/1
M00372055 E/A-Module 3: Input/output DEA0 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:17 E/1
M00372152 E/A-Module 3: Input/output DEA1 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:15 E/1
M00372153 E/A-Module 3: Input/output DEA1 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:15 E/1
M00372154 E/A-Module 3: Input/output DEA1 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:15 E/1
M00372155 E/A-Module 3: Input/output DEA1 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:15 E/1
M00372252 E/A-Module 3: Input/output DEA2 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:13 E/1
M00372253 E/A-Module 3: Input/output DEA2 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:13 E/1
M00372254 E/A-Module 3: Input/output DEA2 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:13 E/1
M00372255 E/A-Module 3: Input/output DEA2 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:13 E/1
M00372352 E/A-Module 3: Input/output DEA3 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:11 E/1
M00372353 E/A-Module 3: Input/output DEA3 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:11 E/1
M00372354 E/A-Module 3: Input/output DEA3 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:11 E/1
M00372355 E/A-Module 3: Input/output DEA3 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:11 E/1
M00372452 E/A-Module 3: Input/output DEA4 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:9 E/1
M00372453 E/A-Module 3: Input/output DEA4 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:9 E/1
M00372454 E/A-Module 3: Input/output DEA4 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:9 E/1
M00372455 E/A-Module 3: Input/output DEA4 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:9 E/1
M00372552 E/A-Module 3: Input/output DEA5 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:7 E/1
M00372553 E/A-Module 3: Input/output DEA5 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:7 E/1
M00372554 E/A-Module 3: Input/output DEA5 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:7 E/1
M00372555 E/A-Module 3: Input/output DEA5 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:7 E/1
M00372652 E/A-Module 3: Input/output DEA6 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:5 E/1
M00372653 E/A-Module 3: Input/output DEA6 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:5 E/1
M00372654 E/A-Module 3: Input/output DEA6 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:5 E/1
M00372655 E/A-Module 3: Input/output DEA6 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:5 E/1
M00372752 E/A-Module 3: Input/output DEA7 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:3 E/1
M00372753 E/A-Module 3: Input/output DEA7 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:3 E/1
M00372754 E/A-Module 3: Input/output DEA7 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:3 E/1
M00372755 E/A-Module 3: Input/output DEA7 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:3 E/1
M00373080 E/A-Module 3: Voltage input E0 – short circuit to ground or open circuit.
Reaction: Fuel level indication in the driver's cab drops to zero.
Remedy: Check input signal on the E/A module or the fuel level sensor.
X632:17 E/1
M00373081 E/A-Module 3: Voltage input E0 – short circuit to supply voltage or open circuit.
Reaction: Fuel level indication in the driver's cab drops to zero.
Remedy: Check input signal on the E/A module or the fuel level sensor.
X632:17 E/1
M00373782 E/A-Module 3: Voltage input E7 – short circuit to ground, open circuit, invalid 10 mA direct current.
Reaction: No reaction.
Remedy: Check input signal on the E/A module or the connected sensor.
X632:3 E/1
M00373783 E/A-Module 3: Voltage input E7 – short circuit to supply voltage, open circuit, no voltage.
Reaction: No reaction.
Remedy: Check input signal on the E/A module or the connected sensor.
X632:3 E/1

 

New Holland Machinery Service – Keep Your Equipment Running Smoothly

We overhaul combine harvester engines and repair excavators, providing professional service support

 

Error Codes for E/A-Modul 3 (cont.) – A0–A3 Outputs, SPI Interface, and LSB-B and CAN Buses

The next part of the E/A-Modul 3 diagnostics (pages 217–221 of the documentation) describes faults of power outputs A0 and A1, bridge outputs A2 and A3, SPI communication with the operating unit, LSB-B network participants (addresses 0–2), and CAN network monitoring.

Error Code Fault Description / System Reaction / Remedy Connector (Stecker) K/W
M00379052 E/A-Module 3: Output A0 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:18 E/1
M00379053 E/A-Module 3: Output A0 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:18 E/1
M00379054 E/A-Module 3: Output A0 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:18 E/1
M00379055 E/A-Module 3: Output A0 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:18 E/1
M00379152 E/A-Module 3: Output A1 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:16 E/1
M00379153 E/A-Module 3: Output A1 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:16 E/1
M00379154 E/A-Module 3: Output A1 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:16 E/1
M00379155 E/A-Module 3: Output A1 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:16 E/1
M00379250 E/A-Module 3: Bridge output A2 – short circuit to ground, unpowered node.
Reaction: Error message on the display.
Remedy: Check output for short circuit, inspect consumer power supply, replace E/A module if necessary.
X633:14 E/1
M00379251 E/A-Module 3: Bridge output A2 – short circuit to supply voltage, overtemperature.
Reaction: Error message on the display.
Remedy: Check output for short circuit, measure output load current, replace E/A module if necessary.
X633:14 E/1
M00379252 E/A-Module 3: Bridge output A2 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:14 E/1
M00379253 E/A-Module 3: Bridge output A2 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:14 E/1
M00379254 E/A-Module 3: Bridge output A2 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:14 E/1
M00379255 E/A-Module 3: Bridge output A2 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:14 E/1
M00379350 E/A-Module 3: Bridge output A3 – short circuit to ground, unpowered node.
Reaction: Error message on the display.
Remedy: Check output for short circuit, inspect consumer power supply, replace E/A module if necessary.
X633:12 E/1
M00379351 E/A-Module 3: Bridge output A3 – short circuit to supply voltage, overtemperature.
Reaction: Error message on the display.
Remedy: Check output for short circuit, measure output load current, replace E/A module if necessary.
X633:12 E/1
M00379352 E/A-Module 3: Bridge output A3 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X633:12 E/1
M00379353 E/A-Module 3: Bridge output A3 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X633:12 E/1
M00379354 E/A-Module 3: Bridge output A3 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X633:12 E/1
M00379355 E/A-Module 3: Bridge output A3 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X633:12 E/1
M00383900 E/A-Module 3: Operating unit control (SPI) – faulty initialization of E/A-Module <> unit data connection.
Reaction: Error indicated on the display.
Remedy: Automatic SPI controller restart and clearing of error state; if occurring frequently, replace E/A module.
X634:1/2/3/5/6/7/8 E/1
M00383902 E/A-Module 3: Operating unit control (SPI) – serious system error of SPI connection (interface).
Reaction: Error indicated on the display.
Remedy: Automatic SPI controller restart and clearing of error state; if occurring frequently, replace E/A module.
X634:1/2/3/5/6/7/8 E/1
M00383905 E/A-Module 3: Operating unit control (SPI) – initialization error, faulty I/O reset.
Reaction: Error indicated on the display.
Remedy: Check wiring, inspect peripheral devices and replace them or the E/A module if necessary.
X634:1/2/3/5/6/7/8 E/1
M00383906 E/A-Module 3: Operating unit control (SPI) – faulty data transfer (invalid check byte).
Reaction: Error indicated on the display.
Remedy: Eliminate electromagnetic interference (EMC/EMV).
X634:1/2/3/5/6/7/8 E/1
M00383907 E/A-Module 3: Operating unit control (SPI) – faulty/missing unit or wrong unit inserted (ID).
Reaction: Error indicated on the display.
Remedy: Connect a functioning peripheral unit; the system will automatically clear the error.
X634:1/2/3/5/6/7/8 E/1
M00383908 E/A-Module 3: Operating unit control (SPI) – faulty data transfer (incorrect number of bytes received).
Reaction: Error indicated on the display.
Remedy: Automatic SPI controller restart and clearing of error state; if occurring frequently, replace E/A module.
X634:1/2/3/5/6/7/8 E/1
M00384050 E/A-Module 3: LSB-B participant address 0 reports incorrect sensor type.
Reaction: Stored in fault memory, response interpreted according to the configured characteristic.
Remedy: Check address assignment in the test system (LSB screen), install the correct sensor.
X633:4/6 E/2
M00384051 E/A-Module 3: LSB-B participant address 0 is not configured for block transfer.
Reaction: Stored in fault memory, block transfer will not be executed.
Remedy: Configuration issue – upload new software.
X633:4/6 E/2
M00384053 E/A-Module 3: LSB-B participant address 0 stopped responding or was disconnected during operation.
Reaction: Stored in fault memory, participant deactivated, data buffer set to 0.
Remedy: Check connection; if the connection is intact, replace the sensor.
X633:4/6 E/1
M00384054 E/A-Module 3: LSB-B participant address 0 has different settings (parameters) than setpoints.
Reaction: Stored in fault memory, sensor data may be incorrect due to wrong configuration.
Remedy: Check setpoint/actual value in the test system (LSB screen), restore default sensor settings.
X633:4/6 E/2
M00384064 E/A-Module 3: LSB-B participant address 0 reports an admissible self-test error.
Reaction: Stored in fault memory, no other reaction – sensor continues to operate properly.
Remedy: Inspect and clean the sensor; if occurring frequently, replace the sensor.
X633:4/6 E/1
M00384065 E/A-Module 3: LSB-B participant address 0 reports an inadmissible self-test error.
Reaction: Stored in fault memory, fault-free operation is no longer guaranteed.
Remedy: Replace the sensor immediately.
X633:4/6 E/2
M00384066 E/A-Module 3: LSB-B participant address 0 has an incompatible software version.
Reaction: Stored in fault memory, system attempts to cooperate with the sensor as far as possible.
Remedy: Replace the sensor with a new one.
X633:4/6 E/2
M00384067 E/A-Module 3: LSB-B participant address 0 does not support the download function.
Reaction: Stored in fault memory, download cannot be executed.
Remedy: Do not perform download operations for this sensor.
X633:4/6 E/1
M00384150 E/A-Module 3: LSB-B participant address 1 reports incorrect sensor type.
Reaction: Stored in fault memory, response interpreted according to the configured characteristic.
Remedy: Check address assignment in the test system (LSB screen), install the correct sensor.
X633:4/6 E/2
M00384151 E/A-Module 3: LSB-B participant address 1 is not configured for block transfer.
Reaction: Stored in fault memory, block transfer will not be executed.
Remedy: Configuration issue – upload new software.
X633:4/6 E/2
M00384153 E/A-Module 3: LSB-B participant address 1 stopped responding or was disconnected during operation.
Reaction: Stored in fault memory, participant deactivated, data buffer set to 0.
Remedy: Check connection; if the connection is intact, replace the sensor.
X633:4/6 E/1
M00384154 E/A-Module 3: LSB-B participant address 1 has different settings (parameters) than setpoints.
Reaction: Stored in fault memory, sensor data may be incorrect due to wrong configuration.
Remedy: Check setpoint/actual value in the test system (LSB screen), restore default sensor settings.
X633:4/6 E/2
M00384164 E/A-Module 3: LSB-B participant address 1 reports an admissible self-test error.
Reaction: Stored in fault memory, no other reaction – sensor continues to operate properly.
Remedy: Inspect and clean the sensor; if occurring frequently, replace the sensor.
X633:4/6 E/1
M00384165 E/A-Module 3: LSB-B participant address 1 reports an inadmissible self-test error.
Reaction: Stored in fault memory, fault-free operation is no longer guaranteed.
Remedy: Replace the sensor immediately.
X633:4/6 E/2
M00384166 E/A-Module 3: LSB-B participant address 1 has an incompatible software version.
Reaction: Stored in fault memory, system attempts to cooperate with the sensor as far as possible.
Remedy: Replace the sensor with a new one.
X633:4/6 E/2
M00384167 E/A-Module 3: LSB-B participant address 1 does not support the download function.
Reaction: Stored in fault memory, download cannot be executed.
Remedy: Do not perform download operations for this sensor.
X633:4/6 E/1
M00384250 E/A-Module 3: LSB-B participant address 2 reports incorrect sensor type.
Reaction: Stored in fault memory, response interpreted according to the configured characteristic.
Remedy: Check address assignment in the test system (LSB screen), install the correct sensor.
X633:4/6 E/2
M00384251 E/A-Module 3: LSB-B participant address 2 is not configured for block transfer.
Reaction: Stored in fault memory, block transfer will not be executed.
Remedy: Configuration issue – upload new software.
X633:4/6 E/2
M00384253 E/A-Module 3: LSB-B participant address 2 stopped responding or was disconnected during operation.
Reaction: Stored in fault memory, participant deactivated, data buffer set to 0.
Remedy: Check connection; if the connection is intact, replace the sensor.
X633:4/6 E/1
M00384254 E/A-Module 3: LSB-B participant address 2 has different settings (parameters) than setpoints.
Reaction: Stored in fault memory, sensor data may be incorrect due to wrong configuration.
Remedy: Check setpoint/actual value in the test system (LSB screen), restore default sensor settings.
X633:4/6 E/2
M00384264 E/A-Module 3: LSB-B participant address 2 reports an admissible self-test error.
Reaction: Stored in fault memory, no other reaction – sensor continues to operate properly.
Remedy: Inspect and clean the sensor; if occurring frequently, replace the sensor.
X633:4/6 E/1
M00384265 E/A-Module 3: LSB-B participant address 2 reports an inadmissible self-test error.
Reaction: Stored in fault memory, fault-free operation is no longer guaranteed.
Remedy: Replace the sensor immediately.
X633:4/6 E/2
M00384266 E/A-Module 3: LSB-B participant address 2 has an incompatible software version.
Reaction: Stored in fault memory, system attempts to cooperate with the sensor as far as possible.
Remedy: Replace the sensor with a new one.
X633:4/6 E/2
M00384267 E/A-Module 3: LSB-B participant address 2 does not support the download function.
Reaction: Stored in fault memory, download cannot be executed.
Remedy: Do not perform download operations for this sensor.
X633:4/6 E/1
M00387252 E/A-Module 3: LSB-B data transfer control detected bus collisions, communication interrupted.
Reaction: Stored in fault memory, controller withdraws from bus, possible reset and network restart.
Remedy: For temporary interference, the error clears automatically; otherwise, check sensor address assignment.
X633:4/6 E/0
M00387255 E/A-Module 3: LSB-B data transfer control – faulty bus connection, short circuit to supply voltage.
Reaction: Stored in fault memory, controller continuously attempts to restart the bus.
Remedy: Check bus cable, disconnect sensors and check bus board for short circuits, inspect bus fuse.
X633:4/6 E/2
M00387256 E/A-Module 3: LSB-B data transfer control – faulty bus connection, no power supply or short circuit to ground.
Reaction: Stored in fault memory, controller continuously attempts to restart the bus.
Remedy: Check bus cable, sensors, and bus board for short circuits and open circuits, check fuse.
X633:4/6 E/2
M00387257 E/A-Module 3: LSB-B data transfer control detected network reset (data transfer restarted).
Reaction: Stored in fault memory, controller restarts and initializes the network.
Remedy: Check bus lines, disconnect sensors one by one from the bus to locate the source of interference, and replace the defective component.
X633:4/6 E/1
M00387258 E/A-Module 3: LSB-B data transfer control detected a participant with an incorrect transmission speed (baud rate).
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Error is automatically eliminated by the system; check sensor address assignment.
X633:4/6 E/0
M00387259 E/A-Module 3: LSB-B data transfer control detected a communication interruption on the bus.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Fault is automatically eliminated by the controller via network restart.
X633:4/6 E/0
M00387260 E/A-Module 3: LSB-B data transfer controller error – command not executed.
Reaction: Stored in fault memory, controller continues operating and waits for bus participant connection.
Remedy: For temporary interference, the error disappears on its own; in case of incorrect configuration, upload new software.
X633:4/6 E/2
M00387261 E/A-Module 3: LSB-B data transfer controller error – undefined message occurred.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: For temporary faults, the system clears the error automatically; otherwise, a software update is required.
X633:4/6 E/2
M00387262 E/A-Module 3: LSB-B data transfer controller error – initialization error.
Reaction: Stored in fault memory, controller restarts and rebuilds the network.
Remedy: Uploading new software is required to eliminate the error.
X633:4/6 E/2
M00389900 E/A-Module 3: CAN data transfer control – internal error during controller register test.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul.
X635:5/6 E/2
M00389901 E/A-Module 3: CAN data transfer control – internal error during controller RAM test.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul.
X635:5/6 E/2
M00389902 E/A-Module 3: CAN data transfer control – software configuration error.
Reaction: Internal error, CAN transmission is interrupted.
Remedy: Replace E/A-Modul, check software (ZE test system).
X635:5/6 E/2
M00389903 E/A-Module 3: CAN data transfer control – transmission interrupted after continuous error.
Reaction: CAN transmission is interrupted.
Remedy: Check bus lines/star point, replace star point or E/A-Modul.
X635:5/6 E/1
M00389910 E/A-Module 3: CAN data transfer control – short-term bus connection error.
Reaction: Module rejoins bus transmission.
Remedy: Check bus lines/star point, disconnect individual network participants and verify if the error clears.
X635:5/6 E/0
M00389911 E/A-Module 3: CAN data transfer control – permanent bus connection error.
Reaction: Cyclic attempts to rejoin the module to bus transmission.
Remedy: Check bus lines/star point, disconnect individual network participants and check if the error has cleared.
X635:5/6 E/1
M00389920 E/A-Module 3: CAN data transfer control – active participant not responding.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: Check error report for missing participants in the ZE test system.
X635:5/6 E/0
M00389921 E/A-Module 3: CAN data transfer control – no active participant responding.
Reaction: Parameterized substitute values are used for receiver signals.
Remedy: If the bus is intact, check the connection of the E/A module to the CAN network or replace the E/A module.
X635:5/6 E/1
M00389950 E/A-Module 3: CAN data transfer control – invalid test system command.
Reaction: No response to an unknown test system control command in the CAN software.
Remedy: Check software (test system).
X635:5/6 E/1
M00394190 E/A-Module 3: Missing LSB bus participant – central processing unit ZE.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and network participant.
- E/1
M00394191 E/A-Module 3: Missing LSB bus participant – E/A-Module 1.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 1.
- E/1
M00394192 E/A-Module 3: Missing LSB bus participant – E/A-Module 2.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 2.
- E/1
M00394194 E/A-Module 3: Missing LSB bus participant – E/A-Module 4.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 4.
- E/1
M00394195 E/A-Module 3: Missing LSB bus participant – E/A-Module 5.
Reaction: Communication with participant impossible; error is cleared after bus communication restart.
Remedy: Check LSB network and E/A module 5.
- E/1

 

New Holland Machinery Service – Keep Your Equipment Running Smoothly

We overhaul combine harvester engines and repair excavators, providing professional service support

 

Error Codes for E/A-Modul 4 (OS-C167 System, DEA0–DEA7 Outputs, E7 Input, and A0–A3 Outputs)

The final section (pages 222–227 of the documentation) contains a list of fault codes for E/A-Modul 4, covering internal errors of the OS-C167 controller, diagnostics of input/output channels DEA0–DEA7 (connector X643), voltage input E7 (connector X642), and power and bridge outputs A0–A3.

Error Code Fault Description / System Reaction / Remedy Connector (Stecker) K/W
M00461001 E/A-Module 4: OS-C167 system error – processor register initialization error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00461002 E/A-Module 4: OS-C167 system error – checksum error during initialization in EPROM/FLASH memory.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00461006 E/A-Module 4: OS-C167 system error – RAM memory initialization error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00461013 E/A-Module 4: OS-C167 system error – incorrect checksum in EPROM/FLASH memory.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00461016 E/A-Module 4: OS-C167 system error – system / controller watchdog timer expired.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00461068 E/A-Module 4: OS-C167 system error – illegal interrupt.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00461071 E/A-Module 4: OS-C167 system error – incorrect configuration or firmware.
Reaction: Error indicated on the display.
Remedy: Re-download software from the central processing unit ZE.
- E/2
M00461080 E/A-Module 4: OS-C167 system error – critical internal software error.
Reaction: Error indicated on the display.
Remedy: Note down error message, switch ignition off/on; if recurring, notify after-sales service.
- E/2
M00461082 E/A-Module 4: OS-C167 system error – hardware watchdog circuit error.
Reaction: Error indicated on the display.
Remedy: Switch ignition off and on; if occurring regularly, replace E/A-Modul.
- E/2
M00461088 E/A-Module 4: OS-C167 system error – configuration does not match software version.
Reaction: Error indicated on the display.
Remedy: Mismatch between EAM software and LICCON configuration – check LICCON configuration and perform a download to EAM.
- E/2
M00472052 E/A-Module 4: Input/output DEA0 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:17 E/1
M00472053 E/A-Module 4: Input/output DEA0 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:17 E/1
M00472054 E/A-Module 4: Input/output DEA0 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:17 E/1
M00472055 E/A-Module 4: Input/output DEA0 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:17 E/1
M00472152 E/A-Module 4: Input/output DEA1 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:15 E/1
M00472153 E/A-Module 4: Input/output DEA1 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:15 E/1
M00472154 E/A-Module 4: Input/output DEA1 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:15 E/1
M00472155 E/A-Module 4: Input/output DEA1 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:15 E/1
M00472252 E/A-Module 4: Input/output DEA2 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:13 E/1
M00472253 E/A-Module 4: Input/output DEA2 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:13 E/1
M00472254 E/A-Module 4: Input/output DEA2 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:13 E/1
M00472255 E/A-Module 4: Input/output DEA2 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:13 E/1
M00472352 E/A-Module 4: Input/output DEA3 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:11 E/1
M00472353 E/A-Module 4: Input/output DEA3 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:11 E/1
M00472354 E/A-Module 4: Input/output DEA3 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:11 E/1
M00472355 E/A-Module 4: Input/output DEA3 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:11 E/1
M00472452 E/A-Module 4: Input/output DEA4 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:9 E/1
M00472453 E/A-Module 4: Input/output DEA4 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:9 E/1
M00472454 E/A-Module 4: Input/output DEA4 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:9 E/1
M00472455 E/A-Module 4: Input/output DEA4 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:9 E/1
M00472552 E/A-Module 4: Input/output DEA5 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:7 E/1
M00472553 E/A-Module 4: Input/output DEA5 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:7 E/1
M00472554 E/A-Module 4: Input/output DEA5 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:7 E/1
M00472555 E/A-Module 4: Input/output DEA5 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:7 E/1
M00472652 E/A-Module 4: Input/output DEA6 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:5 E/1
M00472653 E/A-Module 4: Input/output DEA6 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:5 E/1
M00472654 E/A-Module 4: Input/output DEA6 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:5 E/1
M00472655 E/A-Module 4: Input/output DEA6 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:5 E/1
M00472752 E/A-Module 4: Input/output DEA7 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:3 E/1
M00472753 E/A-Module 4: Input/output DEA7 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:3 E/1
M00472754 E/A-Module 4: Input/output DEA7 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:3 E/1
M00472755 E/A-Module 4: Input/output DEA7 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:3 E/1
M00473782 E/A-Module 4: Voltage input E7 – short circuit to ground, open circuit, invalid 10 mA direct current.
Reaction: No reaction.
Remedy: Check input signal on the E/A module or the connected sensor.
X642:3 E/1
M00473783 E/A-Module 4: Voltage input E7 – short circuit to supply voltage, open circuit, no voltage.
Reaction: No reaction.
Remedy: Check input signal on the E/A module or the connected sensor.
X642:3 E/1
M00479052 E/A-Module 4: Output A0 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:18 E/1
M00479053 E/A-Module 4: Output A0 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:18 E/1
M00479054 E/A-Module 4: Output A0 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:18 E/1
M00479055 E/A-Module 4: Output A0 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:18 E/1
M00479152 E/A-Module 4: Output A1 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:16 E/1
M00479153 E/A-Module 4: Output A1 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:16 E/1
M00479154 E/A-Module 4: Output A1 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:16 E/1
M00479155 E/A-Module 4: Output A1 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:16 E/1
M00479250 E/A-Module 4: Bridge output A2 – short circuit to ground, unpowered node.
Reaction: Error message on the display.
Remedy: Check output for short circuit, inspect consumer power supply, replace E/A module if necessary.
X643:14 E/1
M00479251 E/A-Module 4: Bridge output A2 – short circuit to supply voltage, overtemperature.
Reaction: Error message on the display.
Remedy: Check output for short circuit, measure output load current, replace E/A module if necessary.
X643:14 E/1
M00479252 E/A-Module 4: Bridge output A2 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:14 E/1
M00479253 E/A-Module 4: Bridge output A2 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:14 E/1
M00479254 E/A-Module 4: Bridge output A2 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:14 E/1
M00479255 E/A-Module 4: Bridge output A2 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:14 E/1
M00479350 E/A-Module 4: Bridge output A3 – short circuit to ground, unpowered node.
Reaction: Error message on the display.
Remedy: Check output for short circuit, inspect consumer power supply, replace E/A module if necessary.
X643:12 E/1
M00479351 E/A-Module 4: Bridge output A3 – short circuit to supply voltage, overtemperature.
Reaction: Error message on the display.
Remedy: Check output for short circuit, measure output load current, replace E/A module if necessary.
X643:12 E/1
M00479352 E/A-Module 4: Bridge output A3 – open circuit, load too small, or short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for wire break, measure load current, replace E/A module if necessary.
X643:12 E/1
M00479353 E/A-Module 4: Bridge output A3 – insufficient or missing transistor current supply.
Reaction: Error message on the display.
Remedy: Check power supply and fuse of the E/A module, replace E/A module if necessary.
X643:12 E/1
M00479354 E/A-Module 4: Bridge output A3 – short circuit to supply voltage.
Reaction: Error message on the display.
Remedy: Check output for short circuit, replace E/A module if necessary.
X643:12 E/1
M00479355 E/A-Module 4: Bridge output A3 – overtemperature, short circuit to ground, or overload.
Reaction: Error message on the display.
Remedy: Check output for short circuits, inspect power supply/fuse of the E/A module, replace module if necessary.
X643:12 E/1