Liebherr LTM-1070-4.1 Crane Error Code Diagnostics – I/O Module 2
A comprehensive summary of fault codes for the LICCON control system on the Liebherr LTM-1070-4.1 mobile crane, covering diagnostics of digital and bridge outputs, voltage inputs, the SPI serial bus, LSB-B bus sensors, and CAN communication at the E/A-Modul 2 level (service documentation scope: pages 184–205).
How to Read the LICCON Error Code Structure in the Liebherr LTM-1070-4.1?
The LICCON (Liebherr Computed Control) computer system continuously monitors the electrical circuits of both the carrier and the superstructure. Every diagnostic message logged by E/A-Modul 2 includes an error number, fault description, control system reaction, and recommended repair procedure:
- Error number (with M00 prefix): uniquely identifies the actuator module (the 27xxxx and 28xxxx series apply to E/A Module 2) and the specific signal channel.
- Plug designation (e.g., X622, X623, X624, X625): indicates the physical connector and pin number on the module board where circuit continuity or voltage measurements should be performed.
- Error class (K/W): the letter E indicates an electrical or system fault, while the digits 0, 1, 2 define the priority level and impact on crane operation.
Error Codes for DEA4–DEA7 Outputs, Voltage Inputs, and A0–A3 Outputs
| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
|---|---|---|---|
| M00272453 | E/A-Modul 2: input/output DEA4 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:9 | E/1 |
| M00272454 | E/A-Modul 2: input/output DEA4 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:9 | E/1 |
| M00272455 | E/A-Modul 2: input/output DEA4 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:9 | E/1 |
| M00272552 | E/A-Modul 2: input/output DEA5 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:7 | E/1 |
| M00272553 | E/A-Modul 2: input/output DEA5 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:7 | E/1 |
| M00272554 | E/A-Modul 2: input/output DEA5 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:7 | E/1 |
| M00272555 | E/A-Modul 2: input/output DEA5 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:7 | E/1 |
| M00272652 | E/A-Modul 2: input/output DEA6 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:5 | E/1 |
| M00272653 | E/A-Modul 2: input/output DEA6 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:5 | E/1 |
| M00272654 | E/A-Modul 2: input/output DEA6 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:5 | E/1 |
| M00272655 | E/A-Modul 2: input/output DEA6 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:5 | E/1 |
| M00272752 | E/A-Modul 2: input/output DEA7 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:3 | E/1 |
| M00272753 | E/A-Modul 2: input/output DEA7 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:3 | E/1 |
| M00272754 | E/A-Modul 2: input/output DEA7 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:3 | E/1 |
| M00272755 | E/A-Modul 2: input/output DEA7 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:3 | E/1 |
| M00273481 | E/A-Modul 2: voltage input E4 – short circuit to supply voltage, open circuit. Reaction: compressed air supply symbol 1 flashes on the display. Remedy: check the input signal at the E/A module or sensor. |
X622:9 | E/1 |
| M00273581 | E/A-Modul 2: voltage input E5 – short circuit to supply voltage, open circuit. Reaction: compressed air supply symbol 2 flashes on the display. Remedy: check the input signal at the E/A module or sensor. |
X622:7 | E/1 |
| M00273681 | E/A-Modul 2: voltage input E6 – short circuit to supply voltage, open circuit. Reaction: compressed air supply symbol 3 flashes on the display. Remedy: check the input signal at the E/A module or sensor. |
X622:5 | E/1 |
| M00273782 | E/A-Modul 2: voltage input E7 – short circuit to ground, line break, invalid 10 mA direct current. Reaction: no reaction. Remedy: check the input signal at the E/A module or sensor. |
X622:3 | E/1 |
| M00273783 | E/A-Modul 2: voltage input E7 – short circuit to supply voltage, line break, no voltage. Reaction: no reaction. Remedy: check the input signal at the E/A module or sensor. |
X622:3 | E/1 |
| M00279052 | E/A-Modul 2: output A0 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:18 | E/1 |
| M00279053 | E/A-Modul 2: output A0 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:18 | E/1 |
| M00279054 | E/A-Modul 2: output A0 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:18 | E/1 |
| M00279055 | E/A-Modul 2: output A0 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:18 | E/1 |
| M00279152 | E/A-Modul 2: output A1 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:16 | E/1 |
| M00279153 | E/A-Modul 2: output A1 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:16 | E/1 |
| M00279154 | E/A-Modul 2: output A1 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:16 | E/1 |
| M00279155 | E/A-Modul 2: output A1 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:16 | E/1 |
| M00279250 | E/A-Modul 2: bridge output A2 – short circuit to ground, node without power supply. Reaction: error message on the display. Remedy: check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279251 | E/A-Modul 2: bridge output A2 – short circuit to supply voltage, overtemperature. Reaction: error message on the display. Remedy: check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279252 | E/A-Modul 2: bridge output A2 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279253 | E/A-Modul 2: bridge output A2 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279254 | E/A-Modul 2: bridge output A2 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279255 | E/A-Modul 2: bridge output A2 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:14 | E/1 |
| M00279350 | E/A-Modul 2: bridge output A3 – short circuit to ground, node without power supply. Reaction: error message on the display. Remedy: check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary. |
X623:12 | E/1 |
| M00279351 | E/A-Modul 2: bridge output A3 – short circuit to supply voltage, overtemperature. Reaction: error message on the display. Remedy: check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:12 | E/1 |
| M00279352 | E/A-Modul 2: bridge output A3 – open circuit, load too low, short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. |
X623:12 | E/1 |
| M00279353 | E/A-Modul 2: bridge output A3 – missing or insufficient transistor current supply. Reaction: error message on the display. Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary. |
X623:12 | E/1 |
| M00279354 | E/A-Modul 2: bridge output A3 – short circuit to supply voltage. Reaction: error message on the display. Remedy: check the output circuit for a short circuit; replace the E/A module if necessary. |
X623:12 | E/1 |
| M00279355 | E/A-Modul 2: bridge output A3 – overtemperature, short circuit to ground, or overload. Reaction: error message on the display. Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. |
X623:12 | E/1 |
SPI Interface and LSB-B Bus Participant Error Codes
| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
|---|---|---|---|
| M00283301 | E/A-Modul 2: SPI display unit – faulty data transfer E/A module <> unit (timeout). Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283302 | E/A-Modul 2: SPI display unit – critical system error of the SPI connection (interface). Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283303 | E/A-Modul 2: SPI display unit – line break or short circuit to supply voltage. Reaction: error indication on the display. Remedy: eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283304 | E/A-Modul 2: SPI display unit – line break or short circuit to ground. Reaction: error indication on the display. Remedy: eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283306 | E/A-Modul 2: SPI display unit – faulty data transfer (invalid check byte). Reaction: error indication on the display. Remedy: suppress electromagnetic interference (EMC). |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283307 | E/A-Modul 2: SPI display unit – damaged/missing unit, wrong unit connected (ID). Reaction: error indication on the display. Remedy: check peripheral devices and replace if necessary, check software version, inspect for EMC interference. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283308 | E/A-Modul 2: SPI display unit – faulty data transfer (incorrect number of data bytes received). Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283900 | E/A-Modul 2: control unit operation (SPI) – faulty initialization of data connection E/A module <> unit. Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283902 | E/A-Modul 2: control unit operation (SPI) – critical system error of the SPI connection (interface). Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283905 | E/A-Modul 2: control unit operation (SPI) – initialization error, failed reset of inputs/outputs. Reaction: error indication on the display. Remedy: check wiring, inspect peripheral devices and replace if necessary, check the E/A module and replace if necessary. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283907 | E/A-Modul 2: control unit operation (SPI) – damaged/missing unit, wrong unit connected (ID). Reaction: error indication on the display. Remedy: connect a functional peripheral unit; the system will automatically clear the error. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00283908 | E/A-Modul 2: control unit operation (SPI) – faulty data transfer (incorrect number of data bytes received). Reaction: error indication on the display. Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. |
X624:1/2/3/5/6/7/8 | E/1 |
| M00284050 | E/A-Modul 2: LSB-B participant address 0 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284051 | E/A-Modul 2: LSB-B participant address 0 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284053 | E/A-Modul 2: LSB-B participant address 0 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284054 | E/A-Modul 2: LSB-B participant address 0 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284064 | E/A-Modul 2: LSB-B participant address 0 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284065 | E/A-Modul 2: LSB-B participant address 0 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284066 | E/A-Modul 2: LSB-B participant address 0 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284067 | E/A-Modul 2: LSB-B participant address 0 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00284150 | E/A-Modul 2: LSB-B participant address 1 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284151 | E/A-Modul 2: LSB-B participant address 1 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284153 | E/A-Modul 2: LSB-B participant address 1 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284154 | E/A-Modul 2: LSB-B participant address 1 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284164 | E/A-Modul 2: LSB-B participant address 1 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284165 | E/A-Modul 2: LSB-B participant address 1 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284166 | E/A-Modul 2: LSB-B participant address 1 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284167 | E/A-Modul 2: LSB-B participant address 1 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00284250 | E/A-Modul 2: LSB-B participant address 2 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284251 | E/A-Modul 2: LSB-B participant address 2 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284253 | E/A-Modul 2: LSB-B participant address 2 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284254 | E/A-Modul 2: LSB-B participant address 2 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284264 | E/A-Modul 2: LSB-B participant address 2 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284265 | E/A-Modul 2: LSB-B participant address 2 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284266 | E/A-Modul 2: LSB-B participant address 2 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284267 | E/A-Modul 2: LSB-B participant address 2 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
LSB-B Bus Participant Error Codes
| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
|---|---|---|---|
| M00284350 | E/A-Modul 2: LSB-B participant address 3 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284351 | E/A-Modul 2: LSB-B participant address 3 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284353 | E/A-Modul 2: LSB-B participant address 3 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284354 | E/A-Modul 2: LSB-B participant address 3 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284364 | E/A-Modul 2: LSB-B participant address 3 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284365 | E/A-Modul 2: LSB-B participant address 3 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284366 | E/A-Modul 2: LSB-B participant address 3 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284367 | E/A-Modul 2: LSB-B participant address 3 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00284450 | E/A-Modul 2: LSB-B participant address 4 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284451 | E/A-Modul 2: LSB-B participant address 4 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284453 | E/A-Modul 2: LSB-B participant address 4 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284454 | E/A-Modul 2: LSB-B participant address 4 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284464 | E/A-Modul 2: LSB-B participant address 4 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284465 | E/A-Modul 2: LSB-B participant address 4 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284466 | E/A-Modul 2: LSB-B participant address 4 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284467 | E/A-Modul 2: LSB-B participant address 4 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00284550 | E/A-Modul 2: LSB-B participant address 5 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284551 | E/A-Modul 2: LSB-B participant address 5 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284553 | E/A-Modul 2: LSB-B participant address 5 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284554 | E/A-Modul 2: LSB-B participant address 5 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284564 | E/A-Modul 2: LSB-B participant address 5 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284565 | E/A-Modul 2: LSB-B participant address 5 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284566 | E/A-Modul 2: LSB-B participant address 5 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284567 | E/A-Modul 2: LSB-B participant address 5 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00284650 | E/A-Modul 2: LSB-B participant address 6 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00284651 | E/A-Modul 2: LSB-B participant address 6 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00284653 | E/A-Modul 2: LSB-B participant address 6 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00284654 | E/A-Modul 2: LSB-B participant address 6 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00284664 | E/A-Modul 2: LSB-B participant address 6 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00284665 | E/A-Modul 2: LSB-B participant address 6 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00284666 | E/A-Modul 2: LSB-B participant address 6 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00284667 | E/A-Modul 2: LSB-B participant address 6 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
| M00285050 | E/A-Modul 2: LSB-B participant address 10 reports invalid sensor type. Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. Remedy: check address assignment using the test system (LSB screen), install the correct sensor. |
X623:4/6 | E/2 |
| M00285051 | E/A-Modul 2: LSB-B participant address 10 is not configured for block transfer. Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed. Remedy: configuration issue, upload new software. |
X623:4/6 | E/2 |
| M00285053 | E/A-Modul 2: LSB-B participant address 10 stopped responding or was disconnected during operation. Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. Remedy: check the connection; if the connection is intact, replace the sensor. |
X623:4/6 | E/1 |
| M00285054 | E/A-Modul 2: LSB-B participant address 10 has different settings (parameters) than the preset target values. Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values. |
X623:4/6 | E/2 |
| M00285064 | E/A-Modul 2: LSB-B participant address 10 reports an acceptable self-test error. Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor. |
X623:4/6 | E/1 |
| M00285065 | E/A-Modul 2: LSB-B participant address 10 reports an unacceptable self-test error. Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. Remedy: replace the sensor immediately. |
X623:4/6 | E/2 |
| M00285066 | E/A-Modul 2: LSB-B participant address 10 with a software version that is no longer compatible. Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. Remedy: replace the sensor with a new part. |
X623:4/6 | E/2 |
| M00285067 | E/A-Modul 2: LSB-B participant address 10 does not support the download function. Reaction: entry in error memory, otherwise no reaction; download cannot be performed. Remedy: do not perform the download procedure. |
X623:4/6 | E/1 |
LSB-B Transmission and CAN Communication Error Codes
| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
|---|---|---|---|
| M00287252 | E/A-Modul 2: LSB-B control data transmission detected bus collisions, communication interrupted. Reaction: entry in error memory, controller withdraws from the bus, possible network reset and restart. Remedy: for temporary interference, the error will be cleared automatically by the system; otherwise check sensor address assignment. |
X623:4/6 | E/0 |
| M00287255 | E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, short circuit to supply voltage. Reaction: entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared. Remedy: check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board. |
X623:4/6 | E/2 |
| M00287256 | E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, no power supply/short circuit to ground. Reaction: entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared. Remedy: check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board. |
X623:4/6 | E/2 |
| M00287257 | E/A-Modul 2: LSB-B control data transmission detected a network reset (data transfer restarts). Reaction: entry in error memory, controller reboots and performs a network restart. Remedy: check bus lines, disconnect sensors from the bus one by one until the source of interference is found, replace the damaged part. |
X623:4/6 | E/1 |
| M00287258 | E/A-Modul 2: LSB-B control data transmission detected a participant with an incorrect transmission speed (baud rate) on the bus. Reaction: entry in error memory, controller reboots and performs a network restart. Remedy: the error will be cleared automatically by the system; check sensor address assignment. |
X623:4/6 | E/0 |
| M00287259 | E/A-Modul 2: LSB-B control data transmission detected a communication interruption on the bus. Reaction: entry in error memory, controller reboots and performs a network restart. Remedy: the error will be cleared by the controller via a network restart. |
X623:4/6 | E/0 |
| M00287260 | E/A-Modul 2: LSB-B control data transmission – controller error: no task to execute. Reaction: entry in error memory, controller operates normally and waits for a participant to connect to the bus. Remedy: for temporary interference, the error will be cleared automatically by the system; for incorrect configuration, upload new software. |
X623:4/6 | E/2 |
| M00287261 | E/A-Modul 2: LSB-B control data transmission – controller error: an undefined message occurred. Reaction: entry in error memory, controller reboots and performs a network restart. Remedy: for temporary interference, the error will be cleared automatically by the system; otherwise new software is required to clear the fault. |
X623:4/6 | E/2 |
| M00287262 | E/A-Modul 2: LSB-B control data transmission – controller error: initialization error. Reaction: entry in error memory, controller reboots and performs a network restart. Remedy: uploading new software is required to clear the error. |
X623:4/6 | E/2 |
| M00287530 | E/A-Modul 2: CAN participant engine – participant data transfer cycle exceeded. Reaction: CAN information from the participant exceeded the defined cycle time. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/0 |
| M00287531 | E/A-Modul 2: CAN participant engine – faulty/missing data transfer, max. cycle time exceeded. Reaction: parameterized substitute values will be used for the receiver signals. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/1 |
| M00287630 | E/A-Modul 2: CAN participant transmission – participant data transfer cycle exceeded. Reaction: CAN information from the participant exceeded the defined cycle time. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/0 |
| M00287631 | E/A-Modul 2: CAN participant transmission – faulty/missing data transfer, max. cycle time exceeded. Reaction: parameterized substitute values will be used for the receiver signals. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/1 |
| M00287730 | E/A-Modul 2: CAN participant ABV (ABS/ASR) – participant data transfer cycle exceeded. Reaction: CAN information from the participant exceeded the defined cycle time. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/0 |
| M00287731 | E/A-Modul 2: CAN participant ABV (ABS/ASR) – faulty/missing data transfer, max. cycle time exceeded. Reaction: parameterized substitute values will be used for the receiver signals. Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant. |
X625:5/6 | E/1 |