A comprehensive summary of fault codes for the LICCON control system on the Liebherr LTM-1070-4.1 mobile crane, covering diagnostics of digital and bridge outputs, voltage inputs, the SPI serial bus, LSB-B bus sensors, and CAN communication at the E/A-Modul 2 level (service documentation scope: pages 184–205).

How to Read the LICCON Error Code Structure in the Liebherr LTM-1070-4.1?

The LICCON (Liebherr Computed Control) computer system continuously monitors the electrical circuits of both the carrier and the superstructure. Every diagnostic message logged by E/A-Modul 2 includes an error number, fault description, control system reaction, and recommended repair procedure:

  • Error number (with M00 prefix): uniquely identifies the actuator module (the 27xxxx and 28xxxx series apply to E/A Module 2) and the specific signal channel.
  • Plug designation (e.g., X622, X623, X624, X625): indicates the physical connector and pin number on the module board where circuit continuity or voltage measurements should be performed.
  • Error class (K/W): the letter E indicates an electrical or system fault, while the digits 0, 1, 2 define the priority level and impact on crane operation.

Error Codes for DEA4–DEA7 Outputs, Voltage Inputs, and A0–A3 Outputs

Error Code Error Description / System Reaction / Remedy Plug / Pin Class (K/W)
M00272453 E/A-Modul 2: input/output DEA4 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:9 E/1
M00272454 E/A-Modul 2: input/output DEA4 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:9 E/1
M00272455 E/A-Modul 2: input/output DEA4 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:9 E/1
M00272552 E/A-Modul 2: input/output DEA5 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:7 E/1
M00272553 E/A-Modul 2: input/output DEA5 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:7 E/1
M00272554 E/A-Modul 2: input/output DEA5 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:7 E/1
M00272555 E/A-Modul 2: input/output DEA5 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:7 E/1
M00272652 E/A-Modul 2: input/output DEA6 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:5 E/1
M00272653 E/A-Modul 2: input/output DEA6 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:5 E/1
M00272654 E/A-Modul 2: input/output DEA6 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:5 E/1
M00272655 E/A-Modul 2: input/output DEA6 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:5 E/1
M00272752 E/A-Modul 2: input/output DEA7 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:3 E/1
M00272753 E/A-Modul 2: input/output DEA7 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:3 E/1
M00272754 E/A-Modul 2: input/output DEA7 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:3 E/1
M00272755 E/A-Modul 2: input/output DEA7 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:3 E/1
M00273481 E/A-Modul 2: voltage input E4 – short circuit to supply voltage, open circuit.
Reaction: compressed air supply symbol 1 flashes on the display.
Remedy: check the input signal at the E/A module or sensor.
X622:9 E/1
M00273581 E/A-Modul 2: voltage input E5 – short circuit to supply voltage, open circuit.
Reaction: compressed air supply symbol 2 flashes on the display.
Remedy: check the input signal at the E/A module or sensor.
X622:7 E/1
M00273681 E/A-Modul 2: voltage input E6 – short circuit to supply voltage, open circuit.
Reaction: compressed air supply symbol 3 flashes on the display.
Remedy: check the input signal at the E/A module or sensor.
X622:5 E/1
M00273782 E/A-Modul 2: voltage input E7 – short circuit to ground, line break, invalid 10 mA direct current.
Reaction: no reaction.
Remedy: check the input signal at the E/A module or sensor.
X622:3 E/1
M00273783 E/A-Modul 2: voltage input E7 – short circuit to supply voltage, line break, no voltage.
Reaction: no reaction.
Remedy: check the input signal at the E/A module or sensor.
X622:3 E/1
M00279052 E/A-Modul 2: output A0 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:18 E/1
M00279053 E/A-Modul 2: output A0 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:18 E/1
M00279054 E/A-Modul 2: output A0 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:18 E/1
M00279055 E/A-Modul 2: output A0 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:18 E/1
M00279152 E/A-Modul 2: output A1 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:16 E/1
M00279153 E/A-Modul 2: output A1 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:16 E/1
M00279154 E/A-Modul 2: output A1 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:16 E/1
M00279155 E/A-Modul 2: output A1 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:16 E/1
M00279250 E/A-Modul 2: bridge output A2 – short circuit to ground, node without power supply.
Reaction: error message on the display.
Remedy: check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary.
X623:14 E/1
M00279251 E/A-Modul 2: bridge output A2 – short circuit to supply voltage, overtemperature.
Reaction: error message on the display.
Remedy: check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary.
X623:14 E/1
M00279252 E/A-Modul 2: bridge output A2 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:14 E/1
M00279253 E/A-Modul 2: bridge output A2 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:14 E/1
M00279254 E/A-Modul 2: bridge output A2 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:14 E/1
M00279255 E/A-Modul 2: bridge output A2 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:14 E/1
M00279350 E/A-Modul 2: bridge output A3 – short circuit to ground, node without power supply.
Reaction: error message on the display.
Remedy: check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary.
X623:12 E/1
M00279351 E/A-Modul 2: bridge output A3 – short circuit to supply voltage, overtemperature.
Reaction: error message on the display.
Remedy: check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary.
X623:12 E/1
M00279352 E/A-Modul 2: bridge output A3 – open circuit, load too low, short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary.
X623:12 E/1
M00279353 E/A-Modul 2: bridge output A3 – missing or insufficient transistor current supply.
Reaction: error message on the display.
Remedy: check the power supply and fuse of the E/A module; replace the E/A module if necessary.
X623:12 E/1
M00279354 E/A-Modul 2: bridge output A3 – short circuit to supply voltage.
Reaction: error message on the display.
Remedy: check the output circuit for a short circuit; replace the E/A module if necessary.
X623:12 E/1
M00279355 E/A-Modul 2: bridge output A3 – overtemperature, short circuit to ground, or overload.
Reaction: error message on the display.
Remedy: check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary.
X623:12 E/1

SPI Interface and LSB-B Bus Participant Error Codes

Error Code Error Description / System Reaction / Remedy Plug / Pin Class (K/W)
M00283301 E/A-Modul 2: SPI display unit – faulty data transfer E/A module <> unit (timeout).
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00283302 E/A-Modul 2: SPI display unit – critical system error of the SPI connection (interface).
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00283303 E/A-Modul 2: SPI display unit – line break or short circuit to supply voltage.
Reaction: error indication on the display.
Remedy: eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary.
X624:1/2/3/5/6/7/8 E/1
M00283304 E/A-Modul 2: SPI display unit – line break or short circuit to ground.
Reaction: error indication on the display.
Remedy: eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary.
X624:1/2/3/5/6/7/8 E/1
M00283306 E/A-Modul 2: SPI display unit – faulty data transfer (invalid check byte).
Reaction: error indication on the display.
Remedy: suppress electromagnetic interference (EMC).
X624:1/2/3/5/6/7/8 E/1
M00283307 E/A-Modul 2: SPI display unit – damaged/missing unit, wrong unit connected (ID).
Reaction: error indication on the display.
Remedy: check peripheral devices and replace if necessary, check software version, inspect for EMC interference.
X624:1/2/3/5/6/7/8 E/1
M00283308 E/A-Modul 2: SPI display unit – faulty data transfer (incorrect number of data bytes received).
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00283900 E/A-Modul 2: control unit operation (SPI) – faulty initialization of data connection E/A module <> unit.
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00283902 E/A-Modul 2: control unit operation (SPI) – critical system error of the SPI connection (interface).
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00283905 E/A-Modul 2: control unit operation (SPI) – initialization error, failed reset of inputs/outputs.
Reaction: error indication on the display.
Remedy: check wiring, inspect peripheral devices and replace if necessary, check the E/A module and replace if necessary.
X624:1/2/3/5/6/7/8 E/1
M00283907 E/A-Modul 2: control unit operation (SPI) – damaged/missing unit, wrong unit connected (ID).
Reaction: error indication on the display.
Remedy: connect a functional peripheral unit; the system will automatically clear the error.
X624:1/2/3/5/6/7/8 E/1
M00283908 E/A-Modul 2: control unit operation (SPI) – faulty data transfer (incorrect number of data bytes received).
Reaction: error indication on the display.
Remedy: automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly.
X624:1/2/3/5/6/7/8 E/1
M00284050 E/A-Modul 2: LSB-B participant address 0 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284051 E/A-Modul 2: LSB-B participant address 0 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284053 E/A-Modul 2: LSB-B participant address 0 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284054 E/A-Modul 2: LSB-B participant address 0 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284064 E/A-Modul 2: LSB-B participant address 0 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284065 E/A-Modul 2: LSB-B participant address 0 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284066 E/A-Modul 2: LSB-B participant address 0 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284067 E/A-Modul 2: LSB-B participant address 0 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00284150 E/A-Modul 2: LSB-B participant address 1 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284151 E/A-Modul 2: LSB-B participant address 1 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284153 E/A-Modul 2: LSB-B participant address 1 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284154 E/A-Modul 2: LSB-B participant address 1 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284164 E/A-Modul 2: LSB-B participant address 1 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284165 E/A-Modul 2: LSB-B participant address 1 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284166 E/A-Modul 2: LSB-B participant address 1 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284167 E/A-Modul 2: LSB-B participant address 1 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00284250 E/A-Modul 2: LSB-B participant address 2 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284251 E/A-Modul 2: LSB-B participant address 2 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284253 E/A-Modul 2: LSB-B participant address 2 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284254 E/A-Modul 2: LSB-B participant address 2 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284264 E/A-Modul 2: LSB-B participant address 2 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284265 E/A-Modul 2: LSB-B participant address 2 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284266 E/A-Modul 2: LSB-B participant address 2 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284267 E/A-Modul 2: LSB-B participant address 2 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1

LSB-B Bus Participant Error Codes

Error Code Error Description / System Reaction / Remedy Plug / Pin Class (K/W)
M00284350 E/A-Modul 2: LSB-B participant address 3 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284351 E/A-Modul 2: LSB-B participant address 3 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284353 E/A-Modul 2: LSB-B participant address 3 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284354 E/A-Modul 2: LSB-B participant address 3 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284364 E/A-Modul 2: LSB-B participant address 3 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284365 E/A-Modul 2: LSB-B participant address 3 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284366 E/A-Modul 2: LSB-B participant address 3 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284367 E/A-Modul 2: LSB-B participant address 3 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00284450 E/A-Modul 2: LSB-B participant address 4 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284451 E/A-Modul 2: LSB-B participant address 4 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284453 E/A-Modul 2: LSB-B participant address 4 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284454 E/A-Modul 2: LSB-B participant address 4 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284464 E/A-Modul 2: LSB-B participant address 4 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284465 E/A-Modul 2: LSB-B participant address 4 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284466 E/A-Modul 2: LSB-B participant address 4 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284467 E/A-Modul 2: LSB-B participant address 4 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00284550 E/A-Modul 2: LSB-B participant address 5 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284551 E/A-Modul 2: LSB-B participant address 5 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284553 E/A-Modul 2: LSB-B participant address 5 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284554 E/A-Modul 2: LSB-B participant address 5 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284564 E/A-Modul 2: LSB-B participant address 5 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284565 E/A-Modul 2: LSB-B participant address 5 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284566 E/A-Modul 2: LSB-B participant address 5 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284567 E/A-Modul 2: LSB-B participant address 5 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00284650 E/A-Modul 2: LSB-B participant address 6 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00284651 E/A-Modul 2: LSB-B participant address 6 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00284653 E/A-Modul 2: LSB-B participant address 6 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00284654 E/A-Modul 2: LSB-B participant address 6 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00284664 E/A-Modul 2: LSB-B participant address 6 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00284665 E/A-Modul 2: LSB-B participant address 6 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00284666 E/A-Modul 2: LSB-B participant address 6 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00284667 E/A-Modul 2: LSB-B participant address 6 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1
M00285050 E/A-Modul 2: LSB-B participant address 10 reports invalid sensor type.
Reaction: entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic.
Remedy: check address assignment using the test system (LSB screen), install the correct sensor.
X623:4/6 E/2
M00285051 E/A-Modul 2: LSB-B participant address 10 is not configured for block transfer.
Reaction: entry in error memory, otherwise no reaction; block transfer will not be executed.
Remedy: configuration issue, upload new software.
X623:4/6 E/2
M00285053 E/A-Modul 2: LSB-B participant address 10 stopped responding or was disconnected during operation.
Reaction: entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero.
Remedy: check the connection; if the connection is intact, replace the sensor.
X623:4/6 E/1
M00285054 E/A-Modul 2: LSB-B participant address 10 has different settings (parameters) than the preset target values.
Reaction: entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration.
Remedy: check target/actual parameter value via the test system (LSB screen), restore default sensor values.
X623:4/6 E/2
M00285064 E/A-Modul 2: LSB-B participant address 10 reports an acceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly.
Remedy: check the sensor, clean if necessary; if the error recurs, replace the sensor.
X623:4/6 E/1
M00285065 E/A-Modul 2: LSB-B participant address 10 reports an unacceptable self-test error.
Reaction: entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed.
Remedy: replace the sensor immediately.
X623:4/6 E/2
M00285066 E/A-Modul 2: LSB-B participant address 10 with a software version that is no longer compatible.
Reaction: entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible.
Remedy: replace the sensor with a new part.
X623:4/6 E/2
M00285067 E/A-Modul 2: LSB-B participant address 10 does not support the download function.
Reaction: entry in error memory, otherwise no reaction; download cannot be performed.
Remedy: do not perform the download procedure.
X623:4/6 E/1

LSB-B Transmission and CAN Communication Error Codes

Error Code Error Description / System Reaction / Remedy Plug / Pin Class (K/W)
M00287252 E/A-Modul 2: LSB-B control data transmission detected bus collisions, communication interrupted.
Reaction: entry in error memory, controller withdraws from the bus, possible network reset and restart.
Remedy: for temporary interference, the error will be cleared automatically by the system; otherwise check sensor address assignment.
X623:4/6 E/0
M00287255 E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, short circuit to supply voltage.
Reaction: entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared.
Remedy: check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board.
X623:4/6 E/2
M00287256 E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, no power supply/short circuit to ground.
Reaction: entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared.
Remedy: check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board.
X623:4/6 E/2
M00287257 E/A-Modul 2: LSB-B control data transmission detected a network reset (data transfer restarts).
Reaction: entry in error memory, controller reboots and performs a network restart.
Remedy: check bus lines, disconnect sensors from the bus one by one until the source of interference is found, replace the damaged part.
X623:4/6 E/1
M00287258 E/A-Modul 2: LSB-B control data transmission detected a participant with an incorrect transmission speed (baud rate) on the bus.
Reaction: entry in error memory, controller reboots and performs a network restart.
Remedy: the error will be cleared automatically by the system; check sensor address assignment.
X623:4/6 E/0
M00287259 E/A-Modul 2: LSB-B control data transmission detected a communication interruption on the bus.
Reaction: entry in error memory, controller reboots and performs a network restart.
Remedy: the error will be cleared by the controller via a network restart.
X623:4/6 E/0
M00287260 E/A-Modul 2: LSB-B control data transmission – controller error: no task to execute.
Reaction: entry in error memory, controller operates normally and waits for a participant to connect to the bus.
Remedy: for temporary interference, the error will be cleared automatically by the system; for incorrect configuration, upload new software.
X623:4/6 E/2
M00287261 E/A-Modul 2: LSB-B control data transmission – controller error: an undefined message occurred.
Reaction: entry in error memory, controller reboots and performs a network restart.
Remedy: for temporary interference, the error will be cleared automatically by the system; otherwise new software is required to clear the fault.
X623:4/6 E/2
M00287262 E/A-Modul 2: LSB-B control data transmission – controller error: initialization error.
Reaction: entry in error memory, controller reboots and performs a network restart.
Remedy: uploading new software is required to clear the error.
X623:4/6 E/2
M00287530 E/A-Modul 2: CAN participant engine – participant data transfer cycle exceeded.
Reaction: CAN information from the participant exceeded the defined cycle time.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.
X625:5/6 E/0
M00287531 E/A-Modul 2: CAN participant engine – faulty/missing data transfer, max. cycle time exceeded.
Reaction: parameterized substitute values will be used for the receiver signals.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.
X625:5/6 E/1
M00287630 E/A-Modul 2: CAN participant transmission – participant data transfer cycle exceeded.
Reaction: CAN information from the participant exceeded the defined cycle time.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.
X625:5/6 E/0
M00287631 E/A-Modul 2: CAN participant transmission – faulty/missing data transfer, max. cycle time exceeded.
Reaction: parameterized substitute values will be used for the receiver signals.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.
X625:5/6 E/1
M00287730 E/A-Modul 2: CAN participant ABV (ABS/ASR) – participant data transfer cycle exceeded.
Reaction: CAN information from the participant exceeded the defined cycle time.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.
X625:5/6 E/0
M00287731 E/A-Modul 2: CAN participant ABV (ABS/ASR) – faulty/missing data transfer, max. cycle time exceeded.
Reaction: parameterized substitute values will be used for the receiver signals.
Remedy: check bus lines / star point (neutral point), inspect the faulty bus participant.