LICCON Error Code Diagnostics - Liebherr LTM-1070-4.1 Mobile Crane
The LICCON control system in the Liebherr LTM-1070-4.1 mobile crane monitors the operation of key hydraulic, electronic, engine, and LSB and CAN data bus components. The appearance of an error code on the operator cabin display requires immediate verification to prevent breakdowns and ensure the safety of crane operations.
List of LICCON error codes
| Error code | Error description / System response / Remedy | Connector | Category (C) | Weight (W) |
|---|---|---|---|---|
| M00121151 | ZE 1: LSB subscriber address 11 is not configured for block transfer. Entry in error memory, no reaction to operation. Configuration problem - load new software. |
X635A:z14/z16 | E | 2 |
| M00121153 | ZE 1: LSB subscriber address 11 is not responding or was disconnected during operation. Entry in error memory, subscriber will be deactivated, application data buffer set to 0. Check connection; if OK - replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121154 | ZE 1: LSB subscriber address 11 has different settings (parameters) than default values. Entry in error memory. Sensor data may be incorrect due to improper configuration. Check parameters via LSB screen and restore default values. |
X635A:z14/z16 | E | 2 |
| M00121164 | ZE 1: LSB subscriber address 11 reports a permissible error during self-test. Entry in error memory, sensor working correctly. Check and clean sensor; replace if error recurs. |
X635A:z14/z16 | E | 1 |
| M00121165 | ZE 1: LSB subscriber address 11 reports an impermissible error during self-test. Entry in error memory, faultless operation is not guaranteed. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00121166 | ZE 1: LSB subscriber address 11 has an incompatible software version. Entry in error memory. Attempting to continue work. Replace sensor with new model. |
X635A:z14/z16 | E | 2 |
| M00121167 | ZE 1: LSB subscriber address 11 does not support download function. Entry in error memory. Download operation not possible. Do not perform download operation. |
X635A:z14/z16 | E | 1 |
| M00121204 | ZE 1: LSB subscriber address 12 - signal level exceeded. Error report. Check mounting and pre-damping of the sensor, clean debris, replace if damaged. |
X635A:z14/z16 | E | 1 |
| M00121205 | ZE 1: LSB subscriber address 12 - signal below minimum level. Error report. Check sensor mounting, clear blockages or damage, replace sensor if necessary. |
X635A:z14/z16 | E | 1 |
| M00121218 | ZE 1: LSB subscriber address 12 - excessive temperature. Error report. Operate sensor within permissible temperature range, check heat dissipation. |
X635A:z14/z16 | E | 0 |
| M00121250 | ZE 1: LSB subscriber address 12 reports incorrect sensor type. Entry in error memory. Check address assignment in test system (LSB screen), install correct sensor. |
X635A:z14/z16 | E | 2 |
| M00121251 | ZE 1: LSB subscriber address 12 is not configured for block transfer. Configuration error - load new software. |
X635A:z14/z16 | E | 2 |
| M00121253 | ZE 1: LSB subscriber address 12 is not responding or was withdrawn during operation. Check wire and plug connections or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121254 | ZE 1: LSB subscriber address 12 has inconsistent parameters. Correct sensor parameters on the LSB screen. |
X635A:z14/z16 | E | 2 |
| M00121264 | ZE 1: LSB subscriber address 12 reports permissible error in self-test. Clean sensor, replace if error recurs. |
X635A:z14/z16 | E | 1 |
| M00121265 | ZE 1: LSB subscriber address 12 reports impermissible self-test error. Replace sensor with new one immediately. |
X635A:z14/z16 | E | 2 |
| M00121266 | ZE 1: LSB subscriber address 12 with incompatible software version. Replace sensor with newer component. |
X635A:z14/z16 | E | 2 |
| M00121267 | ZE 1: LSB subscriber address 12 does not support software download. Download procedure not possible. |
X635A:z14/z16 | E | 1 |
| M00121304 | ZE 1: LSB subscriber address 13 - level exceeded. Check sensor mounting and cleanliness. |
X635A:z14/z16 | E | 1 |
| M00121305 | ZE 1: LSB subscriber address 13 - level below minimum. Check whether sensor is damaged by mechanical impact. |
X635A:z14/z16 | E | 1 |
| M00121318 | ZE 1: LSB subscriber address 13 - temperature too high. Ensure proper cooling / allowable operating range. |
X635A:z14/z16 | E | 0 |
| M00121350 | ZE 1: LSB subscriber address 13 reports invalid sensor type. Verify addressing and sensor type in software. |
X635A:z14/z16 | E | 2 |
| M00121351 | ZE 1: LSB subscriber address 13 block transfer not configured. Upload corrected configuration file to control computer. |
X635A:z14/z16 | E | 2 |
| M00121353 | ZE 1: LSB subscriber address 13 no response from sensor. Inspect bus wires, connector X635A, and sensor itself. |
X635A:z14/z16 | E | 1 |
| M00121354 | ZE 1: LSB subscriber address 13 incorrect operating parameters. Reset sensor to factory default settings. |
X635A:z14/z16 | E | 2 |
| M00121364 | ZE 1: LSB subscriber address 13 tolerated self-test error. Clean optical/measuring elements of sensor. |
X635A:z14/z16 | E | 1 |
| M00121365 | ZE 1: LSB subscriber address 13 critical self-test error. Absolute necessity to replace sensor. |
X635A:z14/z16 | E | 2 |
| M00121366 | ZE 1: LSB subscriber address 13 incompatible software. Replace element with newer hardware version. |
X635A:z14/z16 | E | 2 |
| M00121367 | ZE 1: LSB subscriber address 13 no download function. No action. |
X635A:z14/z16 | E | 1 |
| M00121404 | ZE 1: LSB subscriber address 14 maximum value exceeded. Check mounting accuracy and transmitter condition. |
X635A:z14/z16 | E | 1 |
Professional hydraulic and engine dynamometer test bench
We simulate extreme working conditions, guaranteeing 100% efficiency after repair
-
Phone
+48 33 870 42 00
Call us -
WhatsApp
+48 532 161 000
Message on WhatsApp -
E-mail
biuro@wibako.pl
Send e-mail
| Error code | Error description / System response / Remedy | Connector | Category (C) | Weight (W) |
|---|---|---|---|---|
| M00121405 | ZE 1: LSB subscriber address 14 below minimum level. Check sensor mounting, eliminate clogging or damage, replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121418 | ZE 1: LSB subscriber address 14 temperature exceeded. Operate sensor within allowed temperature range, inspect cooling. |
X635A:z14/z16 | E | 0 |
| M00121450 | ZE 1: LSB subscriber address 14 reports invalid sensor type. Check address assignment on LSB screen, install correct sensor. |
X635A:z14/z16 | E | 2 |
| M00121451 | ZE 1: LSB subscriber address 14 block transfer not configured. Configuration problem - load new software. |
X635A:z14/z16 | E | 2 |
| M00121453 | ZE 1: LSB subscriber address 14 no response or disconnected during operation. Check cable/plug connection, replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121454 | ZE 1: LSB subscriber address 14 different parameters than defaults. Reset sensor parameters on LSB screen to factory values. |
X635A:z14/z16 | E | 2 |
| M00121464 | ZE 1: LSB subscriber address 14 tolerated self-test error. Check and clean sensor, replace if fault recurs. |
X635A:z14/z16 | E | 1 |
| M00121465 | ZE 1: LSB subscriber address 14 impermissible error in self-test. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00121466 | ZE 1: LSB subscriber address 14 incompatible software. Replace sensor with brand new component. |
X635A:z14/z16 | E | 2 |
| M00121467 | ZE 1: LSB subscriber address 14 no download support. Download procedure impossible. |
X635A:z14/z16 | E | 1 |
| M00121604 | ZE 1: LSB subscriber address 16 - level exceeded. Check cleanliness and proper installation. |
X635A:z14/z16 | E | 1 |
| M00121605 | ZE 1: LSB subscriber address 16 - level below allowable limit. Check cable and sensor damage. |
X635A:z14/z16 | E | 1 |
| M00121618 | ZE 1: LSB subscriber address 16 - temperature exceeded. Ensure proper thermal conditions. |
X635A:z14/z16 | E | 0 |
| M00121650 | ZE 1: LSB subscriber address 16 reports invalid sensor type. Inspect addressing and replace element. |
X635A:z14/z16 | E | 2 |
| M00121651 | ZE 1: LSB subscriber address 16 block configuration missing. Update host computer software. |
X635A:z14/z16 | E | 2 |
| M00121653 | ZE 1: LSB subscriber address 16 no communication during operation. Check plugs and harness; replace sensor if damaged. |
X635A:z14/z16 | E | 1 |
| M00121654 | ZE 1: LSB subscriber address 16 incorrect parameter settings. Correct parameters in LICCON service software. |
X635A:z14/z16 | E | 2 |
| M00121664 | ZE 1: LSB subscriber address 16 permissible self-test error. Clean and check sensor. |
X635A:z14/z16 | E | 1 |
| M00121665 | ZE 1: LSB subscriber address 16 impermissible error in self-test. Replace sensor with new one. |
X635A:z14/z16 | E | 2 |
| M00121666 | ZE 1: LSB subscriber address 16 incompatible software. Install new sensor. |
X635A:z14/z16 | E | 2 |
| M00121667 | ZE 1: LSB subscriber address 16 no download function. No action. |
X635A:z14/z16 | E | 1 |
| M00121704 | ZE 1: LSB subscriber address 17 - level exceeded. Check installation and absence of pre-damping. |
X635A:z14/z16 | E | 1 |
| M00121705 | ZE 1: LSB subscriber address 17 - level below minimum. Check sensor for mechanical damage. |
X635A:z14/z16 | E | 1 |
| M00121718 | ZE 1: LSB subscriber address 17 - high temperature. Inspect ambient operating temperature. |
X635A:z14/z16 | E | 0 |
| M00121750 | ZE 1: LSB subscriber address 17 wrong sensor type. Check connection correctness and element type. |
X635A:z14/z16 | E | 2 |
| M00121751 | ZE 1: LSB subscriber address 17 block configuration missing. Upload correct system software. |
X635A:z14/z16 | E | 2 |
| M00121753 | ZE 1: LSB subscriber address 17 signal loss during operation. Check electrical harness or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121754 | ZE 1: LSB subscriber address 17 parameters non-compliant with default. Restore factory parameters. |
X635A:z14/z16 | E | 2 |
| M00121764 | ZE 1: LSB subscriber address 17 tolerated self-test error. Clean sensor. |
X635A:z14/z16 | E | 1 |
| M00121765 | ZE 1: LSB subscriber address 17 critical self-test error. Replace sensor. |
X635A:z14/z16 | E | 2 |
| M00121766 | ZE 1: LSB subscriber address 17 incompatible software. Use new sensor. |
X635A:z14/z16 | E | 2 |
| M00121767 | ZE 1: LSB subscriber address 17 download not possible. No action. |
X635A:z14/z16 | E | 1 |
| M00121804 | ZE 1: LSB subscriber address 18 - level exceeded. Check mounting and sensor debris. |
X635A:z14/z16 | E | 1 |
| M00121805 | ZE 1: LSB subscriber address 18 - level below minimum. Eliminate mechanical sensor defect. |
X635A:z14/z16 | E | 1 |
| M00121818 | ZE 1: LSB subscriber address 18 - high temperature. Check heat dissipation. |
X635A:z14/z16 | E | 0 |
| M00121850 | ZE 1: LSB subscriber address 18 wrong sensor type. Check sensor addressing. |
X635A:z14/z16 | E | 2 |
| M00121851 | ZE 1: LSB subscriber address 18 block configuration missing. Load new software. |
X635A:z14/z16 | E | 2 |
| M00121853 | ZE 1: LSB subscriber address 18 no communication. Check cable or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00121854 | ZE 1: LSB subscriber address 18 incorrect parameters. Restore sensor factory values. |
X635A:z14/z16 | E | 2 |
| M00121864 | ZE 1: LSB subscriber address 18 slight self-test error. Clean sensor. |
X635A:z14/z16 | E | 1 |
| M00121865 | ZE 1: LSB subscriber address 18 critical self-test error. Replace sensor. |
X635A:z14/z16 | E | 2 |
| M00121866 | ZE 1: LSB subscriber address 18 inconsistent software version. Use new sensor. |
X635A:z14/z16 | E | 2 |
| M00121867 | ZE 1: LSB subscriber address 18 download unavailable. No action. |
X635A:z14/z16 | E | 1 |
| M00121904 | ZE 1: LSB subscriber address 19 level exceeded. Check sensor and clean debris. |
X635A:z14/z16 | E | 1 |
| M00121905 | ZE 1: LSB subscriber address 19 level below min. Eliminate physical sensor damage. |
X635A:z14/z16 | E | 1 |
| M00121918 | ZE 1: LSB subscriber address 19 temperature limit exceeded. Keep sensor within allowable temperature. |
X635A:z14/z16 | E | 0 |
| M00121950 | ZE 1: LSB subscriber address 19 invalid sensor type. Check address on LSB screen and swap sensor. |
X635A:z14/z16 | E | 2 |
| M00121951 | ZE 1: LSB subscriber address 19 missing configuration. Upload correct software. |
X635A:z14/z16 | E | 2 |
| M00121953 | ZE 1: LSB subscriber address 19 loss of connection. Check connector, replace sensor if necessary. |
X635A:z14/z16 | E | 1 |
| M00121954 | ZE 1: LSB subscriber address 19 incorrect parameters. Reset sensor. |
X635A:z14/z16 | E | 2 |
| M00121964 | ZE 1: LSB subscriber address 19 allowable self-test error. Clean sensor. |
X635A:z14/z16 | E | 1 |
| M00121965 | ZE 1: LSB subscriber address 19 self-test error. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00121966 | ZE 1: LSB subscriber address 19 software incompatible. Replace sensor with new one. |
X635A:z14/z16 | E | 2 |
| M00121967 | ZE 1: LSB subscriber address 19 no download. No action. |
X635A:z14/z16 | E | 1 |
| M00122004 | ZE 1: LSB subscriber address 20 level exceeded. Clean and inspect sensor. |
X635A:z14/z16 | E | 1 |
| M00122005 | ZE 1: LSB subscriber address 20 below minimum level. Check sensor for damage. |
X635A:z14/z16 | E | 1 |
| M00122018 | ZE 1: LSB subscriber address 20 excessive temperature. Ensure appropriate temperature range. |
X635A:z14/z16 | E | 0 |
| M00122050 | ZE 1: LSB subscriber address 20 wrong sensor type. Verify LSB addressing. |
X635A:z14/z16 | E | 2 |
| M00122051 | ZE 1: LSB subscriber address 20 block configuration missing. Load corrected software. |
X635A:z14/z16 | E | 2 |
| M00122053 | ZE 1: LSB subscriber address 20 no response during operation. Check plug/cable or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00122054 | ZE 1: LSB subscriber address 20 invalid parameters. Restore sensor factory defaults. |
X635A:z14/z16 | E | 2 |
| M00122064 | ZE 1: LSB subscriber address 20 slight self-test error. Clean sensor. |
X635A:z14/z16 | E | 1 |
| M00122065 | ZE 1: LSB subscriber address 20 impermissible self-test error. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00122066 | ZE 1: LSB subscriber address 20 incompatible software. Install new sensor. |
X635A:z14/z16 | E | 2 |
| M00122067 | ZE 1: LSB subscriber address 20 no download function. No action. |
X635A:z14/z16 | E | 1 |
Contact us if you need hydraulic repair
Professional repair and reconditioning of hydraulic pumps and motors with dynamometer performance test
-
Phone
+48 33 870 42 00
Call us -
WhatsApp
+48 532 161 000
Message on WhatsApp -
E-mail
biuro@wibako.pl
Send e-mail
| Error code | Error description / System response / Remedy | Connector | Category (C) | Weight (W) |
|---|---|---|---|---|
| M00122104 | ZE 1: LSB subscriber address 21 level exceeded. Clean and inspect sensor. |
X635A:z14/z16 | E | 1 |
| M00122105 | ZE 1: LSB subscriber address 21 level below minimum. Check sensor damage. |
X635A:z14/z16 | E | 1 |
| M00122118 | ZE 1: LSB subscriber address 21 temperature limit exceeded. Keep sensor within permissible temperature. |
X635A:z14/z16 | E | 0 |
| M00122150 | ZE 1: LSB subscriber address 21 wrong sensor type. Check LSB addressing in program. |
X635A:z14/z16 | E | 2 |
| M00122151 | ZE 1: LSB subscriber address 21 block transfer not configured. Software error - load new version. |
X635A:z14/z16 | E | 2 |
| M00122153 | ZE 1: LSB subscriber address 21 disconnected during operation. Check wiring connections, replace sensor. |
X635A:z14/z16 | E | 1 |
| M00122154 | ZE 1: LSB subscriber address 21 different parameter settings. Reset sensor to default settings. |
X635A:z14/z16 | E | 2 |
| M00122164 | ZE 1: LSB subscriber address 21 tolerated self-test error. Check and clean sensor. |
X635A:z14/z16 | E | 1 |
| M00122165 | ZE 1: LSB subscriber address 21 impermissible error in self-test. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00122166 | ZE 1: LSB subscriber address 21 incompatible software. Install new component. |
X635A:z14/z16 | E | 2 |
| M00122167 | ZE 1: LSB subscriber address 21 no download function. No action. |
X635A:z14/z16 | E | 1 |
| M00122204 | ZE 1: LSB subscriber address 22 level exceeded. Clean and inspect sensor condition. |
X635A:z14/z16 | E | 1 |
| M00122205 | ZE 1: LSB subscriber address 22 level below allowable limit. Eliminate mechanical faults and poor contact. |
X635A:z14/z16 | E | 1 |
| M00122218 | ZE 1: LSB subscriber address 22 temperature limit exceeded. Ensure optimal operating temperature. |
X635A:z14/z16 | E | 0 |
| M00122250 | ZE 1: LSB subscriber address 22 reports invalid sensor type. Check type in service software. |
X635A:z14/z16 | E | 2 |
| M00122251 | ZE 1: LSB subscriber address 22 block configuration missing. Load new software. |
X635A:z14/z16 | E | 2 |
| M00122253 | ZE 1: LSB subscriber address 22 signal loss during operation. Check wiring, replace sensor. |
X635A:z14/z16 | E | 1 |
| M00122254 | ZE 1: LSB subscriber address 22 incorrect parameters. Set sensor default parameters. |
X635A:z14/z16 | E | 2 |
| M00122264 | ZE 1: LSB subscriber address 22 slight self-test error. Clean sensor. |
X635A:z14/z16 | E | 1 |
| M00122265 | ZE 1: LSB subscriber address 22 impermissible self-test error. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00122266 | ZE 1: LSB subscriber address 22 incompatible software version. Replace sensor. |
X635A:z14/z16 | E | 2 |
| M00122267 | ZE 1: LSB subscriber address 22 download unavailable. No action. |
X635A:z14/z16 | E | 1 |
| M00122904 | ZE 1: LSB subscriber address 29 signal level exceeded. Check sensor installation, clean dirt. |
X635A:z14/z16 | E | 1 |
| M00122905 | ZE 1: LSB subscriber address 29 signal below minimum level. Eliminate sensor damage or replace element. |
X635A:z14/z16 | E | 1 |
| M00122918 | ZE 1: LSB subscriber address 29 excessive temperature. Operate within allowed temperature range. |
X635A:z14/z16 | E | 0 |
| M00122950 | ZE 1: LSB subscriber address 29 invalid sensor type. Check addressing and install correct sensor. |
X635A:z14/z16 | E | 2 |
| M00122951 | ZE 1: LSB subscriber address 29 block transfer configuration missing. Configuration error - load new software. |
X635A:z14/z16 | E | 2 |
| M00122953 | ZE 1: LSB subscriber address 29 disconnected during operation. Check connections or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00122954 | ZE 1: LSB subscriber address 29 incorrect parameters. Restore sensor factory default values. |
X635A:z14/z16 | E | 2 |
| M00122964 | ZE 1: LSB subscriber address 29 tolerated error in self-test. Clean and inspect sensor. |
X635A:z14/z16 | E | 1 |
| M00122965 | ZE 1: LSB subscriber address 29 critical error in self-test. Replace sensor with new one immediately. |
X635A:z14/z16 | E | 2 |
| M00122966 | ZE 1: LSB subscriber address 29 software incompatible. Replace sensor with a new component. |
X635A:z14/z16 | E | 2 |
| M00122967 | ZE 1: LSB subscriber address 29 no download. No action. |
X635A:z14/z16 | E | 1 |
| M00123004 | ZE 1: LSB subscriber address 30 signal level exceeded. Check sensor mounting and cleanliness. |
X635A:z14/z16 | E | 1 |
| M00123005 | ZE 1: LSB subscriber address 30 signal below min. Fix sensor faults. |
X635A:z14/z16 | E | 1 |
| M00123018 | ZE 1: LSB subscriber address 30 high temperature. Operate within allowed temperature. |
X635A:z14/z16 | E | 0 |
| M00123050 | ZE 1: LSB subscriber address 30 wrong sensor type. Verify addressing in software. |
X635A:z14/z16 | E | 2 |
| M00123051 | ZE 1: LSB subscriber address 30 block configuration missing. Load new software. |
X635A:z14/z16 | E | 2 |
| M00123053 | ZE 1: LSB subscriber address 30 no response during operation. Check cabling or replace sensor. |
X635A:z14/z16 | E | 1 |
| M00123054 | ZE 1: LSB subscriber address 30 incorrect parameters. Restore factory parameters. |
X635A:z14/z16 | E | 2 |
| M00123064 | ZE 1: LSB subscriber address 30 tolerated self-test error. Check and clean sensor. |
X635A:z14/z16 | E | 1 |
| M00123065 | ZE 1: LSB subscriber address 30 impermissible self-test error. Replace sensor immediately. |
X635A:z14/z16 | E | 2 |
| M00123066 | ZE 1: LSB subscriber address 30 incompatible software. Install new component. |
X635A:z14/z16 | E | 2 |
| M00123067 | ZE 1: LSB subscriber address 30 no download function. No action. |
X635A:z14/z16 | E | 1 |
| M00123252 | ZE 1: LSB control data transmission detected bus collisions, communication interrupted. Entry in error memory, controller withdraws from bus. Error resolves automatically if fault is temporary. Otherwise, check sensor addressing. |
X635A:z14/z16 | E | 0 |
| M00123255 | ZE 1: LSB bus connection faulty/damaged, short circuit to supply voltage. Controller attempts to restart the bus. Check bus line, sensors (disconnect one by one), and circuit board for short circuits. Check LSB fuse. |
X635A:z14/z16 | E | 2 |
| M00123256 | ZE 1: LSB bus connection defective, no power supply or short to ground. Check bus cables, sensors, and fuse on LSB board. |
X635A:z14/z16 | E | 2 |
| M00123257 | ZE 1: LSB data transmission detected network reset (transmission restart). Check bus lines, disconnect sensors until fault source is identified. Replace defective element. |
X635A:z14/z16 | E | 1 |
| M00123258 | ZE 1: LSB data transmission detected subscriber with incorrect baud rate. Error resolves automatically or requires checking sensor address assignment. |
X635A:z14/z16 | E | 0 |
| M00123259 | ZE 1: LSB bus communication breakdown detected. Controller restarts and reboots the network. |
X635A:z14/z16 | E | 0 |
| M00123260 | ZE 1: LSB controller error: no command to execute. Normal operation, awaiting subscriber connection. If misconfigured, load new software. |
X635A:z14/z16 | E | 2 |
| M00123261 | ZE 1: LSB controller error: undefined message received. If error persists, loading new software is required. |
X635A:z14/z16 | E | 2 |
| M00123262 | ZE 1: LSB controller error: initialization error. New software required to clear error. |
X635A:z14/z16 | E | 2 |
| M00130570 | ZE 1: Remote control - emergency telescoping selected in LICCON system. Locked by emergency movement. |
- | B | 1 |
| M00130571 | ZE 1: Remote control - manual telescoping mode selected. Service information in system. |
- | B | 1 |
Contact us if your engine requires repair
Comprehensive and major overhauls of internal combustion engines with full diagnostics and load test on a dynamometer
-
Phone
+48 33 870 42 00
Call us -
WhatsApp
+48 532 161 000
Message on WhatsApp -
E-mail
biuro@wibako.pl
Send e-mail
| Error code | Error description / System response / Remedy | Connector | Category (C) | Weight (W) |
|---|---|---|---|---|
| M00130572 | ZE 1: Remote control selected in dual-winch mode. Error report, telescoping locked. Check software configuration and LICCON radio control input. |
- | E | 1 |
| M00130573 | ZE 1: Remote control with Master Switch 3 positioner selected. Error report, telescoping prevented. Check radio control inputs. |
- | E | 1 |
| M00130610 | ZE 1: Data Logger Start: valid crane number not entered. Enter crane number in CRANE ACCEPTANCE program (MO > AK). |
- | E | 1 |
| M00130611 | ZE 1: Data Logger Start: invalid crane number (missing 9 digits). Data logger software stops! Correctly define crane number. |
- | E | 1 |
| M00130620 | ZE 1: Data Logger Init: invalid firmware version. Verify software version compatibility. |
- | E | 1 |
| M00130621 | ZE 1: Data Logger Init: ATA card not initialized. Format/initialize ATA card using "LICCON Manager" software. |
- | E | 1 |
| M00130622 | ZE 1: Data Logger Init: ATA card contains different crane number. Use ATA card with correct crane number or a newly initialized card. |
- | E | 1 |
| M00130623 | ZE 1: Data Logger Init: format file transfer error. If necessary, correct format file "Lnnttt01vvrr.Q" in EPROM 0 memory. |
- | E | 1 |
| M00130630 | ZE 1: Data Logger Transfer: data transmission error. Check connection from LICCON system to data logger. |
- | E | 1 |
| M00130631 | ZE 1: Data Logger Transfer: CSM protocol error. Check cable connections. Re-synchronize. |
- | E | 1 |
| M00130632 | ZE 1: Data Logger Transfer: transmission error (CRC checksum). Check logger connection and signal cable. |
- | E | 1 |
| M00130633 | ZE 1: Data Logger Transfer: STATUS error. Check connection between LICCON central unit and logger. |
- | E | 1 |
| M00130634 | ZE 1: Data Logger Transfer: TAN error. Completely re-synchronize CSM protocol. |
- | E | 1 |
| M00130635 | ZE 1: Data Logger Transfer: write error. Check ATA memory card and logger socket. |
- | E | 1 |
| M00130636 | ZE 1: Data Logger Transfer: missing logger data (SPS-Handshake). Check PLC / SPS controller software function. |
- | E | 1 |
| M00132650 | ZE 1: Telescoping control - track detection fault, more than one track switch reports active. Telescoping locked. Check limit switches and cylinder mounting. |
- | E | 1 |
| M00134201 | ZE 1: Instruments right armrest Master Switch 1X - both directional contacts shorted simultaneously. Deactivation by application. Check line for short circuits, check sensor in armrest. |
- | E | 1 |
| M00134203 | ZE 1: Instruments right armrest Master Switch 1X - directional contact without zero contact. Check power supply, LICCON input, and positioner circuit open faults. |
- | E | 1 |
| M00134205 | ZE 1: Instruments right armrest Master Switch 1X - analog signal shorted to power supply. Check armrest circuit board connections. |
- | E | 1 |
| M00134209 | ZE 1: Instruments right armrest Master Switch 1X - analog signal: open circuit or short to ground. Check power supply and continuity of positioner wires. |
- | E | 1 |
| M00134312 | ZE 1: Instruments left armrest Master Switch 2Y - both directional contacts active simultaneously. Check positioner wiring for short circuits. |
- | E | 1 |
| M00134314 | ZE 1: Instruments left armrest Master Switch 2Y - direction contact without neutral position. Check LICCON input and positioner wiring. |
- | E | 1 |
| M00134316 | ZE 1: Instruments left armrest Master Switch 2Y - analog signal shorted to supply voltage. Check potentiometer / positioner sensor. |
- | E | 1 |
| M00134320 | ZE 1: Instruments left armrest Master Switch 2Y - open circuit in analog line or short to ground. Check plugs and wires to I/O module. |
- | E | 1 |
| M00134801 | ZE 1: Control diagnostics - telescope angle sensor defective or missing signal. Check angle transmitter and its connection, repeat test program. |
- | E | 1 |
| M00134804 | ZE 1: Control diagnostics - hoisting limit switch (knife switch / limit switch) defective or missing. Check winch limit switch, lower hook block. |
- | E | 1 |
| M00134805 | ZE 1: Control diagnostics - length sensor (unreeving) defective or missing. Check cable drum of length sensor and cable connections. |
- | E | 1 |
| M00134820 | ZE 1: Control diagnostics - LS (Load Sensing) pressure sensor defective/missing signal. Check LS pressure transmitter, perform re-test. |
- | E | 1 |
| M00134821 | ZE 1: Control diagnostics - P (main) pressure sensor defective/missing. Check pump P pressure transmitter. |
- | E | 1 |
| M00134822 | ZE 1: Control diagnostics - pressure transmitter in luffing cylinder defective/missing. Check pressure transmitter on boom luffing cylinder. |
- | E | 1 |
| M00134834 | ZE 1: Control diagnostics - pressure cut-off for cylinder retraction out of range. Check retraction pressure cut-off valve. |
- | E | 1 |
| M00134835 | ZE 1: Control diagnostics - pressure cut-off for telescope extension out of allowable range. Check telescopic section valves. |
- | E | 1 |
| M00134836 | ZE 1: Diagnostics - cylinder retraction cut-off pressure out of range. Inspect system pressure. |
- | E | 1 |
| M00134837 | ZE 1: Diagnostics - telescope retraction cut-off pressure out of range. Check proportional valve settings. |
- | E | 1 |
Fast mobile service for construction machinery
Fully equipped workshops and direct travel to the fault location
-
Phone
+48 33 870 42 00
Call us -
WhatsApp
+48 532 161 000
Message on WhatsApp -
E-mail
biuro@wibako.pl
Send e-mail
| Error code | Error description / System response / Remedy | Connector | Category (C) | Weight (W) |
|---|---|---|---|---|
| M00134877 | ZE 1: Diagnostics - telescope retraction initial current above threshold. Check proportional valve coil, hydraulic pump. |
- | E | 1 |
| M00134878 | ZE 1: Diagnostics - telescope retraction initial current below threshold. Check valve / pressure / pump. |
- | E | 1 |
| M00134879 | ZE 1: Diagnostics - telescope extension initial current too high. Inspect electrical condition of proportional valve. |
- | E | 1 |
| M00134880 | ZE 1: Diagnostics - telescope extension initial current too low. Check valve control from output module. |
- | E | 1 |
| M00134881 | ZE 1: Diagnostics - telescope retraction speed too low. Check pump displacement and relief valves. |
- | E | 1 |
| M00134882 | ZE 1: Diagnostics - telescope retraction speed too high. Check throttling and flow control valve. |
- | E | 1 |
| M00134883 | ZE 1: Diagnostics - telescope extension speed too low. Inspect hydraulic pump and control pressure. |
- | E | 1 |
| M00134884 | ZE 1: Diagnostics - telescope extension speed too high. Check setting of hydraulic valves. |
- | E | 1 |
| M00134885 | ZE 1: Diagnostics - telescope retraction hysteresis out of range. Inspect or replace proportional valve. |
- | E | 1 |
| M00134886 | ZE 1: Diagnostics - telescope extension hysteresis out of range. Check proportional flow valve. |
- | E | 1 |
| M00135608 | ZE 1: Telescoping operation - telescope extension shutoff, working area limitation (ABB). Movement shut off by working area limit system. |
- | B | - |
| M00135609 | ZE 1: Telescoping operation - telescope retraction shutoff by working area limitation (ABB). Retract boom from restricted area. |
- | B | - |
| M00135619 | ZE 1: Telescoping operation - shutoff due to missing or incorrect operating mode. Set correct operating mode on LICCON panel. |
- | B | - |
| M00135620 | ZE 1: Telescoping operation - shutoff by load moment limiter (LMB Stop). Permissible load moment exceeded. Reduce radius. |
- | B | - |
| M00135621 | ZE 1: Telescoping operation - extension permission shutoff from LMB. Further extension risks overloading the crane. |
- | B | - |
| M00135622 | ZE 1: Telescoping operation - shutoff due to risk of tipping backward. Exercise caution at high boom angles without load. |
- | B | - |
| M00135630 | ZE 1: Telescoping operation - Master Switch 1 defective or missing. Check condition of joystick 1. |
- | B | - |
| M00135631 | ZE 1: Telescoping operation - Master Switch 2 defective or missing. Check condition of joystick 2. |
- | B | - |
| M00135632 | ZE 1: Telescoping operation - Master Switch 3 defective or missing. Briefly release lever or clear system error. |
- | B | 1 |
| M00135635 | ZE 1: Telescoping operation - right foot switch defective/missing. Check foot switch on cabin floor. |
- | B | - |
| M00135636 | ZE 1: Telescoping operation - left foot switch defective/missing. Release foot pedal or check connection. |
- | B | 1 |
| M00135639 | ZE 1: Telescoping operation - shutoff from operator seat sensor. Operator must take seat. |
- | B | - |
| M00135640 | ZE 1: Telescoping operation - shutoff of length measurement (defective/missing). Check cable drum of telescope length measurement. |
- | B | - |
| M00135644 | ZE 1: Telescoping operation - shutoff, crane engine not running. Start crane engine. For testing, turn on "Control ON engine". |
- | B | - |
| M00135649 | ZE 1: Telescoping operation - shutoff by hoisting limit switch 4. Lower hook block to a safe distance from head. |
- | B | - |
| M00135650 | ZE 1: Telescoping operation - shutoff by hoisting limit switch 1. Lower winch hook 1. |
- | B | - |
| M00135651 | ZE 1: Telescoping operation - shutoff by hoisting limit switch 2. Lower winch hook 2. |
- | B | - |
| M00135652 | ZE 1: Telescoping operation - shutoff by hoisting limit switch 3. Lower auxiliary winch hook. |
- | B | - |
| M00135660 | ZE 1: Telescoping operation - telescope unlocking impossible, cylinder not pinned. Bring TELEMATIK cylinder to pinned position with section. |
- | B | - |
| M00135661 | ZE 1: Telescoping operation - telescope unlocking impossible, LMB permission missing. Clear overload condition on winch / boom. |
- | B | - |
| M00135662 | ZE 1: Telescoping operation - telescope/cylinder unlocking impossible, simultaneous selection. Release switches and select only one operation. |
- | B | - |
| M00135663 | ZE 1: Telescoping operation - cylinder unlocking impossible, telescope not pinned. Pin telescopic section before releasing cylinder. |
- | B | - |
| M00135664 | ZE 1: Telescoping operation - cylinder unlocking impossible, automatic mode enabled. Switch control to manual mode if necessary. |
- | B | - |
| M00135665 | ZE 1: Telescoping operation - telescope unlocking impossible, automatic mode set. Cancel target in automatic mode before changing. |
- | B | - |
| M00135681 | ZE 1: Telescoping operation - hoisting limit switch 1 shutoff defective. Check electrical installation of limit switch 1. |
- | B | - |
| M00135682 | ZE 1: Telescoping operation - hoisting limit switch 2 shutoff defective. Check limit switch 2 on auxiliary block. |
- | B | - |
| M00135683 | ZE 1: Telescoping operation - shutoff limit switch 3 defective. Repair harness or limit switch. |
- | B | - |
| M00135689 | ZE 1: Telescoping operation - hoisting limit switch 4 shutoff defective. Check limit switch 4. |
- | B | - |
| M00135690 | ZE 1: Telescoping operation - cylinder pinning is neither unpinned nor in section pin area. Move cylinder to pinning position at event point. |
- | B | - |
| M00135691 | ZE 1: Telescoping operation - telescope EXTEND/RETRACT movements shut off, cylinder not pinned. Pin cylinder before performing section movement. |
- | B | - |
| M00136019 | ZE 1: Additional equipment operation - shutoff due to incorrect operating mode. Do not switch winch/jib operation while telescoping. |
- | B | - |
| M00137049 | ZE 1: Operator cabin instruments operation - seat sensor inactive, crane movements locked. Sit on the seat or press dead man switch on joystick. Check LICCON input and sensor. |
- | B | 1 |
| M00137201 | ZE 1: Right armrest instruments operation - Master Switch 1X out of neutral position at startup. Release joystick 1X to zero position. Check positioner return spring. |
- | B | 1 |
| M00137312 | ZE 1: Left armrest instruments operation - Master Switch 2Y out of neutral position at startup. Release lever 2Y to center position. |
- | B | 1 |
| M00139800 | ZE 1: Diagnostics operation - test interrupted, Master Switch defective or incorrectly deflected. Pay attention to movement direction, repeat test program. |
- | B | 1 |
| M00139801 | ZE 1: Diagnostics operation - test interrupted, Master Switch positioner defective or missing. Check positioner and repeat diagnostic program. |
- | B | 1 |