# Liebherr LTM-1070-4.1 Crane Error Code Diagnostics – I/O Module 2

A comprehensive summary of fault codes for the LICCON control system on the **Liebherr LTM-1070-4.1** mobile crane, covering diagnostics of digital and bridge outputs, voltage inputs, the **SPI** serial bus, **LSB-B** bus sensors, and **CAN** communication at the E/A-Modul 2 level (service documentation scope: pages 184–205).

## How to Read the LICCON Error Code Structure in the Liebherr LTM-1070-4.1?

The LICCON (Liebherr Computed Control) computer system continuously monitors the electrical circuits of both the carrier and the superstructure. Every diagnostic message logged by E/A-Modul 2 includes an error number, fault description, control system reaction, and recommended repair procedure:

- **Error number (with M00 prefix):** uniquely identifies the actuator module (the 27xxxx and 28xxxx series apply to E/A Module 2) and the specific signal channel.
- **Plug designation (e.g., X622, X623, X624, X625):** indicates the physical connector and pin number on the module board where circuit continuity or voltage measurements should be performed.
- **Error class (K/W):** the letter *E* indicates an electrical or system fault, while the digits *0, 1, 2* define the priority level and impact on crane operation.

### 1. Practical Diagnostics of Power Outputs and Short Circuits in E/A Module 2

Errors from the M00272453 – M00279355 group directly concern the output stages (DEA and bridge outputs A0–A3) in E/A Module 2 of the **Liebherr LTM-1070-4.1** crane. In workshop practice, the most common cause of messages indicating a short circuit to ground, short circuit to supply voltage, or open circuit is not damage to the controller itself, but chafed wiring harnesses near frame joints, hydraulic solenoid valves, or water ingress in multi-pin connectors. Before deciding to replace an expensive E/A Module 2, disconnect plug **X623**, measure the load coil resistance, and verify there is no short to the vehicle chassis.

## Error Codes for DEA4–DEA7 Outputs, Voltage Inputs, and A0–A3 Outputs

| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
| --- | --- | --- | --- |
| M00272453 | **E/A-Modul 2: input/output DEA4 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:9 | E/1 |
| M00272454 | **E/A-Modul 2: input/output DEA4 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:9 | E/1 |
| M00272455 | **E/A-Modul 2: input/output DEA4 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:9 | E/1 |
| M00272552 | **E/A-Modul 2: input/output DEA5 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:7 | E/1 |
| M00272553 | **E/A-Modul 2: input/output DEA5 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:7 | E/1 |
| M00272554 | **E/A-Modul 2: input/output DEA5 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:7 | E/1 |
| M00272555 | **E/A-Modul 2: input/output DEA5 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:7 | E/1 |
| M00272652 | **E/A-Modul 2: input/output DEA6 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:5 | E/1 |
| M00272653 | **E/A-Modul 2: input/output DEA6 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:5 | E/1 |
| M00272654 | **E/A-Modul 2: input/output DEA6 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:5 | E/1 |
| M00272655 | **E/A-Modul 2: input/output DEA6 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:5 | E/1 |
| M00272752 | **E/A-Modul 2: input/output DEA7 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:3 | E/1 |
| M00272753 | **E/A-Modul 2: input/output DEA7 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:3 | E/1 |
| M00272754 | **E/A-Modul 2: input/output DEA7 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:3 | E/1 |
| M00272755 | **E/A-Modul 2: input/output DEA7 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:3 | E/1 |
| M00273481 | **E/A-Modul 2: voltage input E4 – short circuit to supply voltage, open circuit.** *Reaction:* compressed air supply symbol 1 flashes on the display. *Remedy:* check the input signal at the E/A module or sensor. | X622:9 | E/1 |
| M00273581 | **E/A-Modul 2: voltage input E5 – short circuit to supply voltage, open circuit.** *Reaction:* compressed air supply symbol 2 flashes on the display. *Remedy:* check the input signal at the E/A module or sensor. | X622:7 | E/1 |
| M00273681 | **E/A-Modul 2: voltage input E6 – short circuit to supply voltage, open circuit.** *Reaction:* compressed air supply symbol 3 flashes on the display. *Remedy:* check the input signal at the E/A module or sensor. | X622:5 | E/1 |
| M00273782 | **E/A-Modul 2: voltage input E7 – short circuit to ground, line break, invalid 10 mA direct current.** *Reaction:* no reaction. *Remedy:* check the input signal at the E/A module or sensor. | X622:3 | E/1 |
| M00273783 | **E/A-Modul 2: voltage input E7 – short circuit to supply voltage, line break, no voltage.** *Reaction:* no reaction. *Remedy:* check the input signal at the E/A module or sensor. | X622:3 | E/1 |
| M00279052 | **E/A-Modul 2: output A0 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:18 | E/1 |
| M00279053 | **E/A-Modul 2: output A0 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:18 | E/1 |
| M00279054 | **E/A-Modul 2: output A0 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:18 | E/1 |
| M00279055 | **E/A-Modul 2: output A0 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:18 | E/1 |
| M00279152 | **E/A-Modul 2: output A1 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:16 | E/1 |
| M00279153 | **E/A-Modul 2: output A1 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:16 | E/1 |
| M00279154 | **E/A-Modul 2: output A1 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:16 | E/1 |
| M00279155 | **E/A-Modul 2: output A1 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:16 | E/1 |
| M00279250 | **E/A-Modul 2: bridge output A2 – short circuit to ground, node without power supply.** *Reaction:* error message on the display. *Remedy:* check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary. | X623:14 | E/1 |
| M00279251 | **E/A-Modul 2: bridge output A2 – short circuit to supply voltage, overtemperature.** *Reaction:* error message on the display. *Remedy:* check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary. | X623:14 | E/1 |
| M00279252 | **E/A-Modul 2: bridge output A2 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:14 | E/1 |
| M00279253 | **E/A-Modul 2: bridge output A2 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:14 | E/1 |
| M00279254 | **E/A-Modul 2: bridge output A2 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:14 | E/1 |
| M00279255 | **E/A-Modul 2: bridge output A2 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:14 | E/1 |
| M00279350 | **E/A-Modul 2: bridge output A3 – short circuit to ground, node without power supply.** *Reaction:* error message on the display. *Remedy:* check the output for a short circuit, inspect the load current supply; replace the E/A module if necessary. | X623:12 | E/1 |
| M00279351 | **E/A-Modul 2: bridge output A3 – short circuit to supply voltage, overtemperature.** *Reaction:* error message on the display. *Remedy:* check the output for a short circuit, inspect the output load (measure load current); replace the E/A module if necessary. | X623:12 | E/1 |
| M00279352 | **E/A-Modul 2: bridge output A3 – open circuit, load too low, short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output for a broken wire, inspect the output load (measure load current); replace the E/A module if necessary. | X623:12 | E/1 |
| M00279353 | **E/A-Modul 2: bridge output A3 – missing or insufficient transistor current supply.** *Reaction:* error message on the display. *Remedy:* check the power supply and fuse of the E/A module; replace the E/A module if necessary. | X623:12 | E/1 |
| M00279354 | **E/A-Modul 2: bridge output A3 – short circuit to supply voltage.** *Reaction:* error message on the display. *Remedy:* check the output circuit for a short circuit; replace the E/A module if necessary. | X623:12 | E/1 |
| M00279355 | **E/A-Modul 2: bridge output A3 – overtemperature, short circuit to ground, or overload.** *Reaction:* error message on the display. *Remedy:* check the output for short circuits, inspect the E/A module power supply/fuse; replace the E/A module if necessary. | X623:12 | E/1 |

### Professional engine dynamometer

## Load testing allows us to accurately evaluate their performance and confirm proper operation

Fill out the form

- **Phone**
  +48 33 870 42 00
  [Call](tel:+48338704200)
- **WhatsApp**
  +48 532 161 000
  [Message on WhatsApp](https://wa.me/48532161000)
- **E-mail**
  biuro@wibako.pl
  [Send e-mail](mailto:biuro@wibako.pl)

## SPI Interface and LSB-B Bus Participant Error Codes

| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
| --- | --- | --- | --- |
| M00283301 | **E/A-Modul 2: SPI display unit – faulty data transfer E/A module <> unit (timeout).** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283302 | **E/A-Modul 2: SPI display unit – critical system error of the SPI connection (interface).** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283303 | **E/A-Modul 2: SPI display unit – line break or short circuit to supply voltage.** *Reaction:* error indication on the display. *Remedy:* eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283304 | **E/A-Modul 2: SPI display unit – line break or short circuit to ground.** *Reaction:* error indication on the display. *Remedy:* eliminate the short circuit, check peripheral devices and replace if necessary, check the E/A module and replace if necessary. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283306 | **E/A-Modul 2: SPI display unit – faulty data transfer (invalid check byte).** *Reaction:* error indication on the display. *Remedy:* suppress electromagnetic interference (EMC). | X624:1/2/3/5/6/7/8 | E/1 |
| M00283307 | **E/A-Modul 2: SPI display unit – damaged/missing unit, wrong unit connected (ID).** *Reaction:* error indication on the display. *Remedy:* check peripheral devices and replace if necessary, check software version, inspect for EMC interference. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283308 | **E/A-Modul 2: SPI display unit – faulty data transfer (incorrect number of data bytes received).** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283900 | **E/A-Modul 2: control unit operation (SPI) – faulty initialization of data connection E/A module <> unit.** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283902 | **E/A-Modul 2: control unit operation (SPI) – critical system error of the SPI connection (interface).** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283905 | **E/A-Modul 2: control unit operation (SPI) – initialization error, failed reset of inputs/outputs.** *Reaction:* error indication on the display. *Remedy:* check wiring, inspect peripheral devices and replace if necessary, check the E/A module and replace if necessary. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283907 | **E/A-Modul 2: control unit operation (SPI) – damaged/missing unit, wrong unit connected (ID).** *Reaction:* error indication on the display. *Remedy:* connect a functional peripheral unit; the system will automatically clear the error. | X624:1/2/3/5/6/7/8 | E/1 |
| M00283908 | **E/A-Modul 2: control unit operation (SPI) – faulty data transfer (incorrect number of data bytes received).** *Reaction:* error indication on the display. *Remedy:* automatic restart of the SPI driver and clearing of the error state; replace the E/A module if it occurs regularly. | X624:1/2/3/5/6/7/8 | E/1 |
| M00284050 | **E/A-Modul 2: LSB-B participant address 0 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284051 | **E/A-Modul 2: LSB-B participant address 0 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284053 | **E/A-Modul 2: LSB-B participant address 0 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284054 | **E/A-Modul 2: LSB-B participant address 0 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284064 | **E/A-Modul 2: LSB-B participant address 0 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284065 | **E/A-Modul 2: LSB-B participant address 0 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284066 | **E/A-Modul 2: LSB-B participant address 0 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284067 | **E/A-Modul 2: LSB-B participant address 0 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00284150 | **E/A-Modul 2: LSB-B participant address 1 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284151 | **E/A-Modul 2: LSB-B participant address 1 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284153 | **E/A-Modul 2: LSB-B participant address 1 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284154 | **E/A-Modul 2: LSB-B participant address 1 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284164 | **E/A-Modul 2: LSB-B participant address 1 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284165 | **E/A-Modul 2: LSB-B participant address 1 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284166 | **E/A-Modul 2: LSB-B participant address 1 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284167 | **E/A-Modul 2: LSB-B participant address 1 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00284250 | **E/A-Modul 2: LSB-B participant address 2 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284251 | **E/A-Modul 2: LSB-B participant address 2 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284253 | **E/A-Modul 2: LSB-B participant address 2 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284254 | **E/A-Modul 2: LSB-B participant address 2 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284264 | **E/A-Modul 2: LSB-B participant address 2 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284265 | **E/A-Modul 2: LSB-B participant address 2 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284266 | **E/A-Modul 2: LSB-B participant address 2 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284267 | **E/A-Modul 2: LSB-B participant address 2 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |

### We specialize in repairs and overhauls of internal combustion engines

## We overhaul combine harvester engines and repair excavators, providing expert service support

Fill out the form

- **Phone**
  +48 33 870 42 00
  [Call](tel:+48338704200)
- **WhatsApp**
  +48 532 161 000
  [Message on WhatsApp](https://wa.me/48532161000)
- **E-mail**
  biuro@wibako.pl
  [Send e-mail](mailto:biuro@wibako.pl)

## LSB-B Bus Participant Error Codes

| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
| --- | --- | --- | --- |
| M00284350 | **E/A-Modul 2: LSB-B participant address 3 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284351 | **E/A-Modul 2: LSB-B participant address 3 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284353 | **E/A-Modul 2: LSB-B participant address 3 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284354 | **E/A-Modul 2: LSB-B participant address 3 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284364 | **E/A-Modul 2: LSB-B participant address 3 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284365 | **E/A-Modul 2: LSB-B participant address 3 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284366 | **E/A-Modul 2: LSB-B participant address 3 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284367 | **E/A-Modul 2: LSB-B participant address 3 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00284450 | **E/A-Modul 2: LSB-B participant address 4 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284451 | **E/A-Modul 2: LSB-B participant address 4 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284453 | **E/A-Modul 2: LSB-B participant address 4 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284454 | **E/A-Modul 2: LSB-B participant address 4 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284464 | **E/A-Modul 2: LSB-B participant address 4 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284465 | **E/A-Modul 2: LSB-B participant address 4 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284466 | **E/A-Modul 2: LSB-B participant address 4 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284467 | **E/A-Modul 2: LSB-B participant address 4 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00284550 | **E/A-Modul 2: LSB-B participant address 5 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284551 | **E/A-Modul 2: LSB-B participant address 5 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284553 | **E/A-Modul 2: LSB-B participant address 5 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284554 | **E/A-Modul 2: LSB-B participant address 5 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284564 | **E/A-Modul 2: LSB-B participant address 5 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284565 | **E/A-Modul 2: LSB-B participant address 5 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284566 | **E/A-Modul 2: LSB-B participant address 5 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284567 | **E/A-Modul 2: LSB-B participant address 5 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00284650 | **E/A-Modul 2: LSB-B participant address 6 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00284651 | **E/A-Modul 2: LSB-B participant address 6 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00284653 | **E/A-Modul 2: LSB-B participant address 6 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00284654 | **E/A-Modul 2: LSB-B participant address 6 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00284664 | **E/A-Modul 2: LSB-B participant address 6 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00284665 | **E/A-Modul 2: LSB-B participant address 6 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00284666 | **E/A-Modul 2: LSB-B participant address 6 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00284667 | **E/A-Modul 2: LSB-B participant address 6 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |
| M00285050 | **E/A-Modul 2: LSB-B participant address 10 reports invalid sensor type.** *Reaction:* entry in error memory, otherwise no reaction; the response will be interpreted according to the configured type characteristic. *Remedy:* check address assignment using the test system (LSB screen), install the correct sensor. | X623:4/6 | E/2 |
| M00285051 | **E/A-Modul 2: LSB-B participant address 10 is not configured for block transfer.** *Reaction:* entry in error memory, otherwise no reaction; block transfer will not be executed. *Remedy:* configuration issue, upload new software. | X623:4/6 | E/2 |
| M00285053 | **E/A-Modul 2: LSB-B participant address 10 stopped responding or was disconnected during operation.** *Reaction:* entry in error memory, participant will be deactivated, data buffer for the application will be reset to zero. *Remedy:* check the connection; if the connection is intact, replace the sensor. | X623:4/6 | E/1 |
| M00285054 | **E/A-Modul 2: LSB-B participant address 10 has different settings (parameters) than the preset target values.** *Reaction:* entry in error memory or no reaction; sensor data may be inaccurate due to incorrect configuration. *Remedy:* check target/actual parameter value via the test system (LSB screen), restore default sensor values. | X623:4/6 | E/2 |
| M00285064 | **E/A-Modul 2: LSB-B participant address 10 reports an acceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; information only – the sensor continues to operate properly. *Remedy:* check the sensor, clean if necessary; if the error recurs, replace the sensor. | X623:4/6 | E/1 |
| M00285065 | **E/A-Modul 2: LSB-B participant address 10 reports an unacceptable self-test error.** *Reaction:* entry in error memory, otherwise no reaction; fault-free operation is no longer guaranteed. *Remedy:* replace the sensor immediately. | X623:4/6 | E/2 |
| M00285066 | **E/A-Modul 2: LSB-B participant address 10 with a software version that is no longer compatible.** *Reaction:* entry in error memory, otherwise no reaction; the system will attempt to cooperate with the sensor to the extent possible. *Remedy:* replace the sensor with a new part. | X623:4/6 | E/2 |
| M00285067 | **E/A-Modul 2: LSB-B participant address 10 does not support the download function.** *Reaction:* entry in error memory, otherwise no reaction; download cannot be performed. *Remedy:* do not perform the download procedure. | X623:4/6 | E/1 |

### Does the hydraulics in your machine require repair?

## We diagnose faults and restore component efficiency so that machines can operate without disruption.

Fill out the form

- **Phone**
  +48 33 870 42 00
  [Call](tel:+48338704200)
- **WhatsApp**
  +48 532 161 000
  [Message on WhatsApp](https://wa.me/48532161000)
- **E-mail**
  biuro@wibako.pl
  [Send e-mail](mailto:biuro@wibako.pl)

## LSB-B Transmission and CAN Communication Error Codes

| Error Code | Error Description / System Reaction / Remedy | Plug / Pin | Class (K/W) |
| --- | --- | --- | --- |
| M00287252 | **E/A-Modul 2: LSB-B control data transmission detected bus collisions, communication interrupted.** *Reaction:* entry in error memory, controller withdraws from the bus, possible network reset and restart. *Remedy:* for temporary interference, the error will be cleared automatically by the system; otherwise check sensor address assignment. | X623:4/6 | E/0 |
| M00287255 | **E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, short circuit to supply voltage.** *Reaction:* entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared. *Remedy:* check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board. | X623:4/6 | E/2 |
| M00287256 | **E/A-Modul 2: LSB-B control data transmission – bus connection damaged/faulty, no power supply/short circuit to ground.** *Reaction:* entry in error memory, controller continuously attempts to restart the bus; the bus will start immediately after the fault is cleared. *Remedy:* check the bus cable, sensors (disconnect), and bus board for short circuits; check the bus fuse on the board. | X623:4/6 | E/2 |
| M00287257 | **E/A-Modul 2: LSB-B control data transmission detected a network reset (data transfer restarts).** *Reaction:* entry in error memory, controller reboots and performs a network restart. *Remedy:* check bus lines, disconnect sensors from the bus one by one until the source of interference is found, replace the damaged part. | X623:4/6 | E/1 |
| M00287258 | **E/A-Modul 2: LSB-B control data transmission detected a participant with an incorrect transmission speed (baud rate) on the bus.** *Reaction:* entry in error memory, controller reboots and performs a network restart. *Remedy:* the error will be cleared automatically by the system; check sensor address assignment. | X623:4/6 | E/0 |
| M00287259 | **E/A-Modul 2: LSB-B control data transmission detected a communication interruption on the bus.** *Reaction:* entry in error memory, controller reboots and performs a network restart. *Remedy:* the error will be cleared by the controller via a network restart. | X623:4/6 | E/0 |
| M00287260 | **E/A-Modul 2: LSB-B control data transmission – controller error: no task to execute.** *Reaction:* entry in error memory, controller operates normally and waits for a participant to connect to the bus. *Remedy:* for temporary interference, the error will be cleared automatically by the system; for incorrect configuration, upload new software. | X623:4/6 | E/2 |
| M00287261 | **E/A-Modul 2: LSB-B control data transmission – controller error: an undefined message occurred.** *Reaction:* entry in error memory, controller reboots and performs a network restart. *Remedy:* for temporary interference, the error will be cleared automatically by the system; otherwise new software is required to clear the fault. | X623:4/6 | E/2 |
| M00287262 | **E/A-Modul 2: LSB-B control data transmission – controller error: initialization error.** *Reaction:* entry in error memory, controller reboots and performs a network restart. *Remedy:* uploading new software is required to clear the error. | X623:4/6 | E/2 |
| M00287530 | **E/A-Modul 2: CAN participant engine – participant data transfer cycle exceeded.** *Reaction:* CAN information from the participant exceeded the defined cycle time. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/0 |
| M00287531 | **E/A-Modul 2: CAN participant engine – faulty/missing data transfer, max. cycle time exceeded.** *Reaction:* parameterized substitute values will be used for the receiver signals. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/1 |
| M00287630 | **E/A-Modul 2: CAN participant transmission – participant data transfer cycle exceeded.** *Reaction:* CAN information from the participant exceeded the defined cycle time. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/0 |
| M00287631 | **E/A-Modul 2: CAN participant transmission – faulty/missing data transfer, max. cycle time exceeded.** *Reaction:* parameterized substitute values will be used for the receiver signals. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/1 |
| M00287730 | **E/A-Modul 2: CAN participant ABV (ABS/ASR) – participant data transfer cycle exceeded.** *Reaction:* CAN information from the participant exceeded the defined cycle time. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/0 |
| M00287731 | **E/A-Modul 2: CAN participant ABV (ABS/ASR) – faulty/missing data transfer, max. cycle time exceeded.** *Reaction:* parameterized substitute values will be used for the receiver signals. *Remedy:* check bus lines / star point (neutral point), inspect the faulty bus participant. | X625:5/6 | E/1 |